Search icon

OTR WHEEL ENGINEERING, INC. - Florida Company Profile

Company Details

Entity Name: OTR WHEEL ENGINEERING, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

OTR WHEEL ENGINEERING, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 09 Mar 2017 (8 years ago)
Date of dissolution: 28 Mar 2024 (a year ago)
Last Event: CONVERSION
Event Date Filed: 28 Mar 2024 (a year ago)
Document Number: P17000022424
FEI/EIN Number 58-1862442

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 195 Chatillon Road, Ste. 4, Rome, GA, 30161, US
Mail Address: 195 Chatillon Road, Ste. 4, Rome, GA, 30161, US
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
C T CORPORATION SYSTEM Agent -
Rizzi Thomas President 195 Chatillon Road, Rome, GA, 30161
Carr Neil Treasurer 195 Chatillon Road, Rome, GA, 30161
Gormin Jonathan D Vice President 195 Chatillon Road, Rome, GA, 30161
Esson Brad Vice President 195 Chatillon Road, Rome, GA, 30161
Modi Tapan Vice President 195 Chatillon Road, Rome, GA, 30161
Rogers Emily Asst 195 Chatillon Road, Rome, GA, 30161

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2024-04-11 195 Chatillon Road, Ste. 4, Rome, GA 30161 -
CHANGE OF MAILING ADDRESS 2024-04-11 195 Chatillon Road, Ste. 4, Rome, GA 30161 -
CONVERSION 2024-03-28 - CONVERSION MEMBER. NON-QUALIFIED CORPORATION WAS OTR WHEEL ENGINEERING, INC.. CONVERSION NUMBER 100000252361

Documents

Name Date
AMENDED ANNUAL REPORT 2024-04-12
ANNUAL REPORT 2024-04-11
Conversion 2024-03-28
ANNUAL REPORT 2023-02-27
ANNUAL REPORT 2022-05-02
ANNUAL REPORT 2021-02-20
ANNUAL REPORT 2020-03-21
ANNUAL REPORT 2019-02-23
ANNUAL REPORT 2018-04-25
Domestic Profit 2017-03-09

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343763561 0419700 2019-02-05 1044 LANE AVENUE N, JACKSONVILLE, FL, 32254
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-02-06
Emphasis L: FORKLIFT, N: DUSTEXPL, P: DUSTEXPL
Case Closed 2019-02-22
342710142 0419700 2017-10-19 940 EASTPORT RD, JACKSONVILLE, FL, 32218
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2017-10-20
Case Closed 2018-09-13

Related Activity

Type Complaint
Activity Nr 1274161
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19100134 C02 I
Issuance Date 2017-11-01
Current Penalty 3586.0
Initial Penalty 3586.0
Final Order 2017-11-15
Nr Instances 1
Nr Exposed 9
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a. On or about October 19, 2017, the employer provided and had available for voluntary use by the employees N95 dust/particulate respirators and had not provided them with the 29 CFR 1910.134 Appendix D mandatory information. OTR Wheel Engineering, Inc. (formally known as Long's Wheel & Rim, Inc.) was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.134(c)(2)(i), which was contained in OSHA inspection number 1057178, citation number 2, item number 1-a and was affirmed as a final order on August 4, 2015, with respect to a workplace located at 940 Eastport Road, Jacksonville, Florida 32218.
Citation ID 02001A
Citaton Type Other
Standard Cited 19100107 B05 I
Issuance Date 2017-11-01
Abatement Due Date 2017-11-29
Current Penalty 0.0
Initial Penalty 1006.0
Final Order 2017-11-15
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained: a. On or about October 19, 2017, inside the facility spray paint booth, CSHO observed an employee (Painter) using a spray paint gun that was discharging flammable paints and thinners with no visible gauges, audible alarms or pressure activated devices installed in paint spray booth to indicate or ensure that the required air speed was maintained to prevent the accumulation of flammable vapors, thereby exposing the employee to fire and explosion hazards.
Citation ID 02001B
Citaton Type Other
Standard Cited 19100107 B08
Issuance Date 2017-11-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-11-15
Nr Instances 1
Nr Exposed 13
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(8): Each spray booths was not separated from other operations by not less than 3 feet, or by a greater distance, or by such partition or wall as to reduce the danger from juxtaposition of hazardous operations: a. On or about October 19, 2017, outside of the facility spray paint booth, CSHO observed the storage of flammable chemicals (three 55 gallon drums of Xylene and waste paints) stored within 14-inches of the spray paint booth, exposing employees to fire and explosion hazards in the event of catastrophic event occurring at the spray paint booth or the chemical storage operational areas.
Citation ID 02002A
Citaton Type Other
Standard Cited 19100134 I05 IV
Issuance Date 2017-11-01
Abatement Due Date 2017-11-29
Current Penalty 0.0
Initial Penalty 1006.0
Final Order 2017-11-15
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated so as to have a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change: a. On or about October 19, 2017, the employer did not ensure that compressor used to supply breathing air to respirators had a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change, thereby exposing a painting employee to respiratory illness or injury.
Citation ID 02002B
Citaton Type Other
Standard Cited 19100134 I06
Issuance Date 2017-11-01
Abatement Due Date 2017-11-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-11-15
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(i)(6): For compressors that are not oil-lubricated, the employer did not ensure that carbon monoxide levels in the breathing air did not exceed 10 ppm: a. On or about October 19, 2017, the employer did not ensure that compressor used to supply breathing air to employee respirators did not exceed carbon monoxide levels of 10 ppm, thereby exposing a painting employee to respiratory illness or injury.

Date of last update: 02 Apr 2025

Sources: Florida Department of State