Search icon

SMASH BROTHERS INC - Florida Company Profile

Company Details

Entity Name: SMASH BROTHERS INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

SMASH BROTHERS INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 22 Feb 2017 (8 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: P17000017734
FEI/EIN Number 82-0623058

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 427A POLK AVE, ORANGE PARK, FL, 32065, US
Mail Address: 427A POLK AVE, ORANGE PARK, FL, 32065, US
ZIP code: 32065
County: Clay
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
WOODS STEVENS GJR President 427A POLK AVE, ORANGE PARK, FL, 32065
WOODS STEVEN GJR Agent 427A POLK AVE, ORANGE PARK, FL, 32065

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
CHANGE OF PRINCIPAL ADDRESS 2018-03-20 427A POLK AVE, ORANGE PARK, FL 32065 -
CHANGE OF MAILING ADDRESS 2018-03-20 427A POLK AVE, ORANGE PARK, FL 32065 -
REGISTERED AGENT ADDRESS CHANGED 2018-03-20 427A POLK AVE, ORANGE PARK, FL 32065 -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J23000197632 ACTIVE 1000000951084 CLAY 2023-04-25 2033-05-03 $ 1,498.82 STATE OF FLORIDA, DEPARTMENT OF REVENUE, JACKSONVILLE SERVICE CENTER, 921 N DAVIS ST STE 250A, JACKSONVILLE FL322096825
J19000790715 ACTIVE 1000000850602 CLAY 2019-12-02 2029-12-04 $ 468.65 STATE OF FLORIDA, DEPARTMENT OF REVENUE, JACKSONVILLE SERVICE CENTER, 921 N DAVIS ST STE 250A, JACKSONVILLE FL322096825

Documents

Name Date
ANNUAL REPORT 2018-03-20
Domestic Profit 2017-02-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342243961 0419700 2017-04-12 3808 COASTAL COVE CIRCLE LOT 74 (COASTAL COVE SUBDIVISION), JACKSONVILLE, FL, 32224
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2017-04-12
Emphasis L: FALL, P: FALL
Case Closed 2020-10-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2017-05-19
Current Penalty 2173.0
Initial Penalty 2173.0
Final Order 2017-07-13
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical agents: a. On or about April 12, 2017, at the first level rooftop, an employee operating a Hitachi pneumatic nail gun to perform framing work was not wearing eye protection, being exposed to struck-by hazards by flying debris or nails.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-05-19
Current Penalty 2716.0
Initial Penalty 2716.0
Final Order 2017-07-13
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about April 12, 2017, at the second level rooftop, employees conducting roof sheathing operations on a 6:12 pitch roof were exposed to a 19 feet 2 inches and higher fall hazard to ground level without the use of personal fall arrest system, safety net system or guardrail system. b. On or about April 12, 2017, at the first level rooftop, employees conducting roof sheathing operations on a 5:12 pitch roof were exposed to a 9 feet 6 inches fall hazard to ground level without the use of personal fall arrest system, safety net system or guardrail system.
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2017-05-19
Abatement Due Date 2017-07-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-07-13
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): A safety and health program was not initiated and maintained to provide compliance with the general safety and health provisions of the standard: a. On or about April 12 2017, at the worksite, a safety and health program had not been initiated and maintained which addressed the following basic elements: 1. Management Commitment and Leadership A. Policy statement: goals established, issued, and communicated to employees. B. Program Reviewed Annually. C. Participation in safety meetings, inspections; agenda item in meet D. Adequate commitment of resources. E. Safety rules and procedures incorporated into site operations. F. Management observations of safety rules. 2. Assignment of Responsibility A. Safety designee on site, knowledgeable, and accountable. B. Supervisors' (including foremen) safety and health responsibilities understood. C. Employees adherence to safety rules. 3. Identification and Control of Hazards A. Periodic site inspection program involving supervisors. B. Preventive controls in place (PPE, Maintenance, Engineering Controls). C. Action taken to address hazards. D. Safety Committee, where appropriate. E. Technical reference materials available. 4. Training and Education A. Supervisors receive basic safety and health training. B. Specialized training taken when needed. C. Existence of an employee training program, which is ongoing and effective. 5. Recordkeeping and Hazard Analysis
Citation ID 03001
Citaton Type Other
Standard Cited 19030019 C01
Issuance Date 2017-11-06
Abatement Due Date 2017-12-26
Current Penalty 305.0
Initial Penalty 305.0
Final Order 2017-12-01
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a. Smash Brothers Inc. was previously cited for a violation of this Occupational Safety and Health Standard or its equivalent standard, 29 CFR 1926.0020(b)(1), which was contained in OSHA Inspection number 1224396, Citation number 02, Item number 001, issued on May 19, 2017. The employer failed to provided abatement certification for this citation within 10 calendar days after the abatement date, exposing employees to physical injury and health hazards.