342906088
|
0419700
|
2018-01-25
|
126 PALISADES DRIVE, SAINT AUGUSTINE, FL, 32092
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-02-20
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-10-15
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2018-02-26 |
Abatement Due Date |
2018-03-08 |
Current Penalty |
3880.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-04-03 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) On or about January 25, 2018: An employees was operating a pneumatic nail gun while performing framing activities and was not provided with eye protection. The employee was building a creek on the garage roof area. Employees was exposed to eye injuries. b) On or about January 25, 2018: An employees was using a pneumatic nail gun while performing framing activities and was not provided with eye protection. The employee was performing finishes to a box detail at the front of the house. Employees was exposed to eye injuries. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-02-26 |
Abatement Due Date |
2018-03-08 |
Current Penalty |
9054.0 |
Initial Penalty |
9054.0 |
Final Order |
2018-04-03 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about January 25, 2018: An employee was observed installing roof sheathing at a height of 20-feet and a roof pitch of about 6:12 and the employee was not protected by guardrail system, safety net, or personal fall arrest system, nor was employee provided with an alternative fall protection measure. Employee was exposed to a 20-feet fall hazard. b) On or about January 25, 2018: An employee was observed installing a creek at the garage area at a height of 10-feet and the employee was not protected by guardrail system, safety net, or personal fall arrest system, nor was employee provided with an alternative fall protection measure. Employee was exposed to a 10-feet fall hazard. c) On or about January 25, 2018: An employee was observed performing finishes to a box detail at the front of the house at a height of 10-feet and the employee was not protected by guardrail system, safety net, or personal fall arrest system, nor was employee provided with an alternative fall protection measure. Employee was exposed to a 10-feet fall hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 II |
Issuance Date |
2018-02-26 |
Abatement Due Date |
2018-03-08 |
Current Penalty |
6467.0 |
Initial Penalty |
6467.0 |
Final Order |
2018-04-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) On or about January 25, 2018: Employees were using a stairway to access the second floor and it was not provided with a stairrail. Employees were exposed to a fall hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260503 A01 |
Issuance Date |
2018-02-26 |
Abatement Due Date |
2018-03-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about January 25, 2018: Three employees were observed performing framing activities at heights higher than 6-feet from next lower level which exposed them to a fall hazard and such employees were not provided with training that will allow them to recognized such hazards and equipped them on how to minimized them. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19030019 C01 |
Issuance Date |
2018-06-25 |
Abatement Due Date |
2018-08-10 |
Current Penalty |
726.0 |
Initial Penalty |
726.0 |
Final Order |
2018-07-19 |
Nr Instances |
1 |
Nr Exposed |
60 |
Related Event Code (REC) |
Imminent Danger |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1903.19(c)(1): 29 CFR 1903.19(c)(1): The employer failed to certify to OSHA (the Agency) that the following item(s) were abated within 10 calendar days after the abatement date: a. On or about March 8, 2018, the employer failed to provide documentation and certification of abatement for violations that occurred on January 25, 2018 at the job site located at 126, Palisades Drive, Florida 32092. |
|
|
342872520
|
0419700
|
2018-01-10
|
6618 AZALEA PARK (LOT 4) (THE CROSSINGS AT BARTRAM SUBDIVISION), JACKSONVILLE, FL, 32258
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-01-10
|
Emphasis |
L: FALL
|
Case Closed |
2020-10-15
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2018-02-23 |
Current Penalty |
7761.0 |
Initial Penalty |
7761.0 |
Final Order |
2018-04-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about January 10, 2018, on the roof frame, employees operating a Hitachi pneumatic nail gun to perform framing work were not wearing eye protection being exposed to flying debris or nails. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-02-23 |
Current Penalty |
9053.0 |
Initial Penalty |
9053.0 |
Final Order |
2018-04-03 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about January 10, 2018, on the roof frame, employees performing framing work were not protected from a 19 feet 7 inches fall hazard by the use of fall protection system. |
|
|
342851755
|
0419700
|
2017-12-27
|
3040 LUCENA LANE, JACKSONVILLE, FL, 32246
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-12-27
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-10-15
|
Related Activity
Type |
Inspection |
Activity Nr |
1285206 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1291359 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2018-02-26 |
Current Penalty |
6468.0 |
Initial Penalty |
6468.0 |
Final Order |
2018-04-03 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about December 27, 2017, a carpenter employee using a Dewalt Circular Saw to cut blocks was exposed to an eye injury hazard in that he was not wearing protective eyewear while exposed to flying debris. b. On or about December 27, 2017, a carpenter employee installing blocks in the trusses above the garage with a pneumatic nailer was exposed to an eye injury hazard in that he was not wearing protective eyewear. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-02-26 |
Current Penalty |
9054.0 |
Initial Penalty |
9054.0 |
Final Order |
2018-04-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On or about December 27, 2017, a carpenter employee installing blocks in the trusses above the right-side garage was exposed to a 12 feet fall hazard to the concrete floor in that he was not protected by a fall protection system. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19261053 B01 |
Issuance Date |
2018-02-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about December 27, 2017, at the wall in the right-side garage, the access ladder to the roof truss webbing did not extend 36 inches above the upper landing surface. |
|
|