Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2017-08-28 | No data | No data |
Name | Date |
---|---|
Domestic Profit | 2016-11-15 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342552296 | 0419700 | 2017-08-14 | 96392 SOAP CREEK DR., FERNANDINA BEACH, FL, 32034 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1250800 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1255208 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1255175 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2017-09-29 |
Current Penalty | 3549.0 |
Initial Penalty | 5070.0 |
Final Order | 2017-10-24 |
Nr Instances | 1 |
Nr Exposed | 5 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about August 09, 2017, on the second floor frame, employees conducting framing operation were not protected from a 10 feet 9 inches fall hazard by the use of fall protection system. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2017-05-23 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2020-08-19 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2017-07-06 |
Current Penalty | 5070.0 |
Initial Penalty | 5070.0 |
Final Order | 2017-08-24 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about May 22, 2017, on the 7:12 pitch roof sheathing and trusses employees were attaching roof sheathing without the use of a complete fall protection system, being exposed to 9-foot 9-inch to 10-foot 3-inch fall hazards. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2017-07-06 |
Current Penalty | 3622.0 |
Initial Penalty | 3622.0 |
Final Order | 2017-08-24 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about May 22, 2017, inside the framed residence employees used 6-foot and 8-foot portable A frame step ladders that did not extend at least 3 feet above the upper landing surface to gain access to the bottom of the roof trusses, exposed to from 6-foot to 10-foot fall hazards. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2017-07-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-08-24 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. On or about May 22, 2017, inside the framed residence employees used the top or top step of the 6-foot and 8-foot portable A frame step ladders to gain access to the bottom of the roof trusses, exposed to 6-foot and 8-foot fall hazards. |