Search icon

AZUAY CONSTRUCTION INC - Florida Company Profile

Company Details

Entity Name: AZUAY CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

AZUAY CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 08 Nov 2016 (8 years ago)
Date of dissolution: 28 Sep 2018 (7 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 28 Sep 2018 (7 years ago)
Document Number: P16000089889
FEI/EIN Number APPLIED FOR

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 274 JOCELYN DR, DAVENPORT, FL, 33897, US
Mail Address: 274 JOCELYN DR, DAVENPORT, FL, 33897, US
ZIP code: 33897
County: Polk
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
URGILES LUIS Director 274 JOCELYN DR, DAVENPORT, FL, 33897
URGILES LUIS Agent 274 JOCELYN DR, DAVENPORT, FL, 33897
URGILES LUIS President 274 JOCELYN DR, DAVENPORT, FL, 33897

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2018-09-28 - -
REINSTATEMENT 2017-09-27 - -
REGISTERED AGENT NAME CHANGED 2017-09-27 URGILES, LUIS -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2017-09-22 - -

Documents

Name Date
REINSTATEMENT 2017-09-27
Domestic Profit 2016-11-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342866118 0420600 2018-01-05 8121 ROMA DUNE DR., WESLEY CHAPEL, FL, 33543
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-01-05
Emphasis L: FALL, P: FALL
Case Closed 2021-02-17

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2018-02-26
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2018-03-23
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) 8121 Roma Dune Dr. - Employees in the process of decking the 5 in 12 slope (vertical to horizontal) roof, were exposed to fall hazards up to 18'9", in that, fall protection equipment was not installed or utilized, observed on or about 01/05/2018.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2018-02-26
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2018-03-23
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) 8121 Roma Dune Dr. - Employees were exposed to a 9'4" fall hazard, in that, the extension ladder did not extend 3 foot above the roof edge, observed on or about 01/05/2018.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2018-02-26
Abatement Due Date 2018-04-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-03-23
Nr Instances 1
Nr Exposed 7
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. (a) The employer does not have fall protection training certification for employees, observed on or about 01/05/2018.
342756624 0420600 2017-11-07 28878 GOLDEN VISTA BLVD., WESLEY CHAPEL, FL, 33543
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-11-07
Emphasis L: FALL, P: FALL
Case Closed 2021-02-17

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2018-02-27
Current Penalty 5174.0
Initial Penalty 5174.0
Final Order 2018-03-26
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about 11/07/2017 at the apartments complex of Altis at Wiregrass, Golden Vista Blvd. Wesley Chapel, employees were exposed to a 29 foot fall hazard, in that, fall protection was not used. Employees were installing plywood panels on the roof with a 7/12 pitched roof.

Date of last update: 03 Apr 2025

Sources: Florida Department of State