Search icon

LEYY CARPENTRY INC - Florida Company Profile

Company Details

Entity Name: LEYY CARPENTRY INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

LEYY CARPENTRY INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 07 Oct 2016 (9 years ago)
Document Number: P16000081957
FEI/EIN Number 81-4082530

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 4748 ESCOBAR AVE, APT A, NAPLES, FL, 34103, US
Mail Address: 4748 ESCOBAR AVE, APT A, NAPLES, FL, 34103, US
ZIP code: 34103
County: Collier
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
CHAVEZ LESBY E President 4748 ESCOBAR AVE APT A, NAPLES, FL, 34103
CHAVEZ LESBY E Agent 4748 ESCOBAR AVE, NAPLES, FL, 34103

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J17000681603 TERMINATED 1000000766036 COLLIER 2017-12-15 2027-12-20 $ 907.72 STATE OF FLORIDA, DEPARTMENT OF REVENUE, NAPLES SERVICE CENTER, 3845 BECK BLVD STE 831, NAPLES FL341141218

Documents

Name Date
ANNUAL REPORT 2024-04-16
ANNUAL REPORT 2023-04-24
ANNUAL REPORT 2022-04-21
ANNUAL REPORT 2021-04-27
ANNUAL REPORT 2020-06-29
ANNUAL REPORT 2019-04-30
ANNUAL REPORT 2018-04-28
ANNUAL REPORT 2017-04-28
Domestic Profit 2016-10-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343665576 0418800 2018-12-13 1650 CRAYTON ROAD, NAPLES, FL, 34102
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-12-13
Emphasis L: FALL
Case Closed 2024-04-04

Related Activity

Type Referral
Activity Nr 1409619
Safety Yes
Type Inspection
Activity Nr 1368119
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2019-04-26
Abatement Due Date 2019-05-22
Current Penalty 3410.0
Initial Penalty 3410.0
Final Order 2019-05-23
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 12/13/2018, at 1650 Crayton Road, in Naples, Florida, an employee without fall protection was exposed to a fall hazard while working from a hanging bracket scaffold that was not fully planked.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2019-04-26
Abatement Due Date 2019-05-22
Current Penalty 3410.0
Initial Penalty 3410.0
Final Order 2019-05-23
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about 12/13/2018, at 1650 Crayton Road, in Naples, Florida, an employee without fall protection was exposed to a fall hazard of 16 feet to ground level while working from a hanging bracket scaffold that had wooden uprights on the ground that did not have base plates or mudsills.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2019-04-26
Abatement Due Date 2019-05-22
Current Penalty 3410.0
Initial Penalty 3410.0
Final Order 2019-05-23
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: On or about 12/13/2018, at 1650 Crayton Road, in Naples, Florida, an employee was not provided with a means to safely access a hanging bracket scaffold, thus exposing the worker to a fall hazard of 16 feet to ground level.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2019-04-26
Abatement Due Date 2019-05-22
Current Penalty 3410.0
Initial Penalty 3410.0
Final Order 2019-05-23
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level: On or about 12/13/2018, at 1650 Crayton Road, in Naples, Florida, an employee without fall protection was exposed to a fall hazard of 16 feet to ground level while working from a hanging bracket scaffold.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-04-26
Abatement Due Date 2019-05-22
Current Penalty 3410.0
Initial Penalty 3410.0
Final Order 2019-05-23
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about 12/13/2018, at 1650 Crayton Road, in Naples, Florida, employees working on a sloped roof with a 4:12 pitch on a residential home in construction and not wearing fall protection, were exposed to a fall hazard of 16 feet to ground level.
Citation ID 01006
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2019-04-26
Abatement Due Date 2019-05-02
Current Penalty 1705.0
Initial Penalty 1705.0
Final Order 2019-05-23
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On or about 12/13/2018, at 1650 Crayton Road, in Naples, Florida, employees were using a ladder that did not extend at least 3 feet above the landing to access a roof exposing them to a fall hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19030019 C01
Issuance Date 2019-08-12
Abatement Due Date 2019-08-16
Current Penalty 319.0
Initial Penalty 319.0
Final Order 2019-09-19
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) On or about 07/08/2019, the employer failed to submit certification of corrective action for citation 1, item 1 issued on 4/26/2019 with an abatement due date of 5/22/2019. b) On or about 07/08/2019, the employer failed to submit certification of corrective action for citation 1, item 2 issued on 4/26/2019 with an abatement due date of 5/22/2019. c) On or about 07/08/2019, the employer failed to submit certification of corrective action for citation 1, item 3 issued on 4/26/2019 with an abatement due date of 5/22/2019. d) On or about 07/08/2019, the employer failed to submit certification of corrective action for citation 1, item 4 issued on 4/26/2019 with an abatement due date of 5/22/2019. e) On or about 07/08/2019, the employer failed to submit certification of corrective action for citation 1, item 5 issued on 4/26/2019 with an abatement due date of 5/22/2019. f) On or about 07/08/2019, the employer failed to submit certification of corrective action for citation 1, item 6 issued on 4/26/2019 with an abatement due date of 5/02/2019.