Search icon

URANGA FLORIDA CONSTRUCTION CORP - Florida Company Profile

Company Details

Entity Name: URANGA FLORIDA CONSTRUCTION CORP
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

URANGA FLORIDA CONSTRUCTION CORP is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 30 Sep 2016 (9 years ago)
Document Number: P16000080168
FEI/EIN Number 81-4087470

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 250 NW 129 AVE, MIAMI, FL, 33182, US
Mail Address: 250 NW 129 ave, MIAMI, FL, 33182, US
ZIP code: 33182
County: Miami-Dade
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
URANGA CARLOS A President 250 NW 129 AVE, MIAMI, FL, 33182
Uranga Ricardo Vice President 9215 SW 35 ST, Miami, FL, 33165
URANGA CARLOS A Agent 250 NW 129 AVE, MIAMI, FL, 33182

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2025-01-30 7825 SW 128 ST, Pinecrest, FL 33156 -
CHANGE OF MAILING ADDRESS 2025-01-30 7825 SW 128 ST, Pinecrest, FL 33156 -
REGISTERED AGENT ADDRESS CHANGED 2025-01-30 7825 SW 128 ST, Pinecrest, FL 33156 -
REGISTERED AGENT ADDRESS CHANGED 2024-04-24 250 NW 129 AVE, MIAMI, FL 33182 -
CHANGE OF PRINCIPAL ADDRESS 2023-04-27 250 NW 129 AVE, MIAMI, FL 33182 -
CHANGE OF MAILING ADDRESS 2023-04-27 250 NW 129 AVE, MIAMI, FL 33182 -

Documents

Name Date
ANNUAL REPORT 2025-01-30
ANNUAL REPORT 2024-04-24
ANNUAL REPORT 2023-04-27
ANNUAL REPORT 2022-04-24
ANNUAL REPORT 2021-04-26
ANNUAL REPORT 2020-03-18
ANNUAL REPORT 2019-04-23
ANNUAL REPORT 2018-04-29
ANNUAL REPORT 2017-04-11
Domestic Profit 2016-09-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347310617 0418800 2024-02-28 304 N KROME AVENUE, HOMESTEAD, FL, 33030
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-02-28
Emphasis N: FALL, P: FALL
Case Closed 2024-06-03

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2024-05-06
Current Penalty 2115.6
Initial Penalty 3526.0
Final Order 2024-05-29
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or above February 28th, 2024, at 304 N. Krome Avenue, Homestead, Florida, an employee was exposed to 12-foot fall hazards while preparing rebar columns while positioned approximately 3 feet from the edge of an unprotected floor without a means of protection. b) On or above February 28th , 2024, at 304 N. Krome Avenue , Homestead, Florida, employees were exposed to 12-foot fall hazards while walking/working nearby an open elevator shaft.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2024-05-06
Current Penalty 2115.6
Initial Penalty 3526.0
Final Order 2024-05-29
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76cm) whichever is less were not equipped with one stair-rail system along each unprotected side or edge: On or above February 28th , 2024, at 304 N. Krome Avenue , Homestead, Florida, employees were exposed to 12-foot-fall hazards while using a staircase without handrails and with an unprotected side to gain access to the second floor.