Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-09-21
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-01-27
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-11-21 |
Abatement Due Date |
2018-12-04 |
Current Penalty |
2328.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-12-26 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: At the jobsite located at 9912 Batchelder Terr. Palmetto, FL a.For employees engaged in roof decking on a roof with a slope of 6 by 12 that were exposed to a fall of approximately 10 foot to the ground, on or about 09/21/18. b. For employee engaged in roof decking on a 6 by 12 sloped roof that was exposed to a fall of approximately 12 foot to the ground, on or about 09/21/18. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2018-11-21 |
Abatement Due Date |
2018-12-04 |
Current Penalty |
997.8 |
Initial Penalty |
1663.0 |
Final Order |
2018-12-26 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:(a) a. At the jobsite located at 9912 Batchelder Terr. Palmetto, FL, employees were using two extension ladders to access the roof of the house and were not extended 3 feet above the edge of the roof, as observed on or about 09/21/18. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2018-11-21 |
Abatement Due Date |
2018-12-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-26 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. At the job site at 9912 Batchelder Terr. Palmetto, FL, employer did not develop and maintain a written hazard communication program for the use of gasoline as fuel for the air compressor used to operate the nail guns. |
|
|