Search icon

Y. J. QUALITY CONSTRUCTION INC

Company Details

Entity Name: Y. J. QUALITY CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Active
Date Filed: 11 Aug 2016 (9 years ago)
Document Number: P16000066777
FEI/EIN Number 81-3573367
Address: 5005 FAIRPORT AVE, DELEON SPRINGS, FL 32130
Mail Address: 5005 FAIRPORT AVE, DELEON SPRINGS, FL 32130
ZIP code: 32130
County: Volusia
Place of Formation: FLORIDA

Agent

Name Role Address
QUALITY TAX & ACCOUNTING SERVICES LLC Agent 3113 S RIDGEWOOD AVE, SOUTH DAYTONA, FL 32119

President

Name Role Address
RAMOS, LILIANA President 5005 FAIRPORT AVE, DELEON SPRINGS, FL 32130

Vice President

Name Role Address
RAMOS, LILIANA Vice President 5005 FAIRPORT AVE, DELEON SPRINGS, FL 32130

Secretary

Name Role Address
RAMOS, LILIANA Secretary 5005 FAIRPORT AVE, DELEON SPRINGS, FL 32130

Treasurer

Name Role Address
RAMOS, LILIANA Treasurer 5005 FAIRPORT AVE, DELEON SPRINGS, FL 32130

Events

Event Type Filed Date Value Description
REGISTERED AGENT NAME CHANGED 2022-03-22 QUALITY TAX & ACCOUNTING SERVICES LLC No data
REGISTERED AGENT ADDRESS CHANGED 2022-03-22 3113 S RIDGEWOOD AVE, SOUTH DAYTONA, FL 32119 No data

Documents

Name Date
ANNUAL REPORT 2024-04-18
ANNUAL REPORT 2023-03-27
ANNUAL REPORT 2022-03-22
ANNUAL REPORT 2021-03-16
ANNUAL REPORT 2020-06-09
ANNUAL REPORT 2019-04-27
ANNUAL REPORT 2018-03-29
ANNUAL REPORT 2017-03-29
Domestic Profit 2016-08-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347072704 0419700 2023-11-01 116 SEASIDE POINT, FLAGLER BEACH, FL, 32136
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2023-11-01
Emphasis N: CTARGET

Related Activity

Type Complaint
Activity Nr 2096947
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2024-02-27
Current Penalty 2939.0
Initial Penalty 2939.0
Final Order 2024-04-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee use appropriate eye / face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: At a residential construction site located at 116 Seaside Point Flagler Beach FL: On or about November 1, 2023, the employer exposed employee to eye or face hazards from flying particles, specifically; employee was working with pneumatic nail guns, saws and metal hammers without the use of eye or face protection.
Citation ID 02001
Citaton Type Other
Standard Cited 19260100 A
Issuance Date 2024-02-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-04-15
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: At a residential construction site located at 16 Seaside Point Flagler Beach FL: On or about November 1, 2023, the employer exposed employees to struck-by hazards from falling objects, while framing in that they were not protected by hardhats from overhead hazards.
342194206 0419700 2017-03-23 22 SEDGEWICK TRAIL, PALM COAST, FL, 32164
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2017-03-23
Emphasis P: FALL, L: FALL
Case Closed 2018-03-23

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-04-24
Current Penalty 1955.4
Initial Penalty 3259.0
Final Order 2017-05-18
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about March 23, 2017 two employees were installing plywood sheathing on a new 6:12 pitch steep slope residential roof and were not protected by any means of personal fall protection, guardrails, or safety nets, exposing them to falls in excess of 9 feet to the ground below.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A02
Issuance Date 2017-04-24
Current Penalty 1629.6
Initial Penalty 2716.0
Final Order 2017-05-18
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(2): The employer shall ensure that each affected employee uses eye protection that provides side protection when there is a hazard from flying objects. Detachable side protectors (e.g. clip-on or slide-on side shields) meeting the pertinent requirements of this section are acceptable. a. On or about March 23, 2017 the employer did not assure employees using pneumatic nail guns were protected from impact of flying objects to the eyes, by the use of safety glasses or goggles. One employee was observed installing roof sheathing and truss blocking using an Hitachi Pneumatic Nail Gun and was not wearing safety glasses, or goggles.

Date of last update: 19 Feb 2025

Sources: Florida Department of State