Search icon

HIGH RISE QUEEN INC - Florida Company Profile

Company Details

Entity Name: HIGH RISE QUEEN INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

HIGH RISE QUEEN INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 20 Jul 2016 (9 years ago)
Date of dissolution: 07 Jul 2020 (5 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 07 Jul 2020 (5 years ago)
Document Number: P16000060841
FEI/EIN Number 81-3410121

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 120 Tarracina Way, Daytona Beach, FL, 32117, US
Mail Address: 120 Tarracina Way, Daytona Beach, FL, 32117, US
ZIP code: 32117
County: Volusia
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
HAHN ERIKA Director 120 Tarracina Way, Daytona Beach, FL, 32117
Hahn Michael Director 120 Tarracina Way, Daytona Beach, FL, 32117
Price Daniel Agent 1248 Robbin Dr., Port Orange, FL, 32129

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2020-07-07 - -
CHANGE OF PRINCIPAL ADDRESS 2019-06-14 120 Tarracina Way, Daytona Beach, FL 32117 -
CHANGE OF MAILING ADDRESS 2019-06-14 120 Tarracina Way, Daytona Beach, FL 32117 -
REGISTERED AGENT NAME CHANGED 2017-04-27 Price, Daniel -
REGISTERED AGENT ADDRESS CHANGED 2017-04-27 1248 Robbin Dr., Port Orange, FL 32129 -

Documents

Name Date
VOLUNTARY DISSOLUTION 2020-07-07
ANNUAL REPORT 2020-02-17
AMENDED ANNUAL REPORT 2019-06-14
ANNUAL REPORT 2019-01-23
AMENDED ANNUAL REPORT 2018-12-04
AMENDED ANNUAL REPORT 2018-09-13
AMENDED ANNUAL REPORT 2018-06-04
ANNUAL REPORT 2018-03-27
ANNUAL REPORT 2017-04-27
Domestic Profit 2016-07-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344433859 0419700 2019-11-07 1575 OCEAN SHORE BLVD, ORMOND BEACH, FL, 32174
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2019-11-07
Emphasis L: FALL

Related Activity

Type Accident
Activity Nr 1516095

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100027 B01 II
Issuance Date 2020-02-20
Current Penalty 4048.0
Initial Penalty 4048.0
Contest Date 2020-06-17
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.27(b)(1)(ii): The employer did not ensure that no employee uses any anchorage before the employer has obtained written information from the building owner that each anchorage meets the requirements of paragraph (b)(1)(i) of this section and that the employer must keep the information for the duration of the job. a. On or about November 7, 2019, the employer did not obtain or maintain any information from the building owner establishing that the anchor points on the roof, including but not limited to, the angle iron stanchion of an air-conditioning mounting bracket, met the 5,000-pound requirement of this standard, exposing employees to fall hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100027 B02 V
Issuance Date 2020-02-20
Abatement Due Date 2020-04-07
Current Penalty 13494.0
Initial Penalty 13494.0
Contest Date 2020-06-17
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.27(b)(2)(v): 29 CFR 1910.27(b)(2)(v): The employer did not ensure that the rope descent system had proper rigging, including anchorages and tiebacks, with particular emphasis on providing tiebacks when counterweights, cornice hooks, or similar non-permanent anchorages were used: a. On or about November 7, 2019, the working line rope and the safety life line rope of the rope descent system were not secured to the Versabeam spine handle nor to the anchor point on the roof, in that the butterfly loop of the poachers knot was not connected back through the D ring carabiner, exposing employees to a 120-foot fall hazard
Citation ID 01003
Citaton Type Serious
Standard Cited 19100027 B02 VI
Issuance Date 2020-02-20
Current Penalty 4048.0
Initial Penalty 4048.0
Contest Date 2020-06-17
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.27(b)(2)(vi): The employer did not ensure that each employee using a rope descent system, used a separate, independent personal fall arrest system that met the requirements of subpart I of this part: a. On or about November 7, 2019, both the working line rope and the safety "life" line rope of the rope descent system were attached to the same angle iron stanchion of an air-conditioning mounting bracket on the roof, exposing employees to 120-foot fall hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19100030 A03 IV
Issuance Date 2020-02-20
Abatement Due Date 2020-04-07
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2020-06-17
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.30(a)(3)(iv): The employer did not train each employee on the correct use of personal fall protection systems and equipment, including, but not limited to, proper hook-up, anchoring, and tie-off techniques, and methods of equipment inspection and storage, as specified by the manufacturer: a. On or about November 7, 2019, the employer did not train the employees in the correct use of personal fall protection systems and equipment, including, but not limited to, proper hook-up, anchoring, and tie-off techniques, and methods of equipment inspection and storage, as specified by the manufacturer, exposing them to fall hazards.

Date of last update: 01 Apr 2025

Sources: Florida Department of State