Search icon

C & K DRYWALL SERVICES INC - Florida Company Profile

Company Details

Entity Name: C & K DRYWALL SERVICES INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

C & K DRYWALL SERVICES INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 30 Jun 2016 (9 years ago)
Document Number: P16000056402
FEI/EIN Number 81-3177549

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2 PINE CONE DR, PALM COAST, FL, 32137, US
Mail Address: 2 PINE CONE DR, PALM COAST, FL, 32137, US
ZIP code: 32137
County: Flagler
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MORENO SERGIO President 2 PINE CONE DR, PALM COAST, FL, 32137
MORENO SERGIO Agent 2 PINE CONE DR, PALM COAST, FL, 32137

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2017-03-21 2 PINE CONE DR, UNIT 351206, PALM COAST, FL 32137 -
CHANGE OF MAILING ADDRESS 2017-03-21 2 PINE CONE DR, UNIT 351206, PALM COAST, FL 32137 -
REGISTERED AGENT ADDRESS CHANGED 2017-03-21 2 PINE CONE DR, UNIT 351206, PALM COAST, FL 32137 -

Documents

Name Date
ANNUAL REPORT 2025-01-08
ANNUAL REPORT 2024-04-28
ANNUAL REPORT 2023-04-18
ANNUAL REPORT 2022-04-11
ANNUAL REPORT 2021-02-21
ANNUAL REPORT 2020-05-27
ANNUAL REPORT 2019-04-17
ANNUAL REPORT 2018-04-19
ANNUAL REPORT 2017-03-21
Domestic Profit 2016-06-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345275234 0419700 2021-04-27 22 OCEAN RIDGE BOULEVARD NORTH, PALM COAST, FL, 32137
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2021-04-27
Emphasis L: FALL
Case Closed 2022-06-08

Related Activity

Type Inspection
Activity Nr 1527514
Safety Yes
Type Inspection
Activity Nr 1531325
Safety Yes
Type Inspection
Activity Nr 1527463
Safety Yes
Type Inspection
Activity Nr 1527519
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2021-09-27
Current Penalty 5461.0
Initial Penalty 5461.0
Final Order 2021-11-10
Nr Instances 3
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On the second floor, at the elevator landing, at 22 Ocean Ridge Boulevard North in Palm Coast Florida: On or about April 15, 2021, the employer exposed three drywall employees to a 19 feet fall hazard down the open elevator shaft, in that they were not protected by a fall protection system after removal of the guardrails by employees of C & K Drywall Services, Inc. b. On the third floor, at the elevator landing, at 22 Ocean Ridge Boulevard North in Palm Coast Florida: On or about April 15, 2021, and at times prior, the employer exposed three C & K Drywall Services, Inc. drywall employees to a 29 feet fall hazard down the open elevator shaft, in that they were not protected by a fall protection system after removal of the guardrails by employees of C & K Drywall Services, Inc. c. On the second floor, at the elevator landing, at 22 Ocean Ridge Boulevard North in Palm Coast Florida: On or about April 15, 2021, and at times prior, the employer exposed three C & K Drywall, Inc. drywall employees to a 7 feet fall hazard over the top of the 2.2 feet high partial wall down to the steps of the main foyer stairs, in that not protected by a fall protection system and no top rail or baluster rail had been installed.

Date of last update: 01 Apr 2025

Sources: Florida Department of State