Search icon

AA CONTRACTING SERVICES INC - Florida Company Profile

Company Details

Entity Name: AA CONTRACTING SERVICES INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

AA CONTRACTING SERVICES INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 09 May 2016 (9 years ago)
Date of dissolution: 22 Sep 2017 (8 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 22 Sep 2017 (8 years ago)
Document Number: P16000041394
FEI/EIN Number 812603369

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2041 DIXIE BELLE DR, ORLANDO, FL, 32812, US
Mail Address: 2041 DIXIE BELLE DR, ORLANDO, FL, 32812, US
ZIP code: 32812
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MEJIA-ORDONEZ DINA E President 2041 DIXIE BELLE DR, ORLANDO, FL, 32812
ORDONEZ ALEXI Vice President 2041 DIXIE BELLE DR, ORLANDO, FL, 32812
MEJIA-ORDONEZ DINA E Agent 2041 DIXIE BELLE DR, ORLANDO, FL, 32812

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2017-09-22 - -
AMENDMENT 2016-12-30 - -

Documents

Name Date
Amendment 2016-12-30
Domestic Profit 2016-05-09

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341930402 0420600 2016-11-18 4612 FAIRY TALE, KISSIMMEE, FL, 34746
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2016-11-18
Emphasis L: FALL
Case Closed 2019-12-20

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2017-01-27
Abatement Due Date 2017-02-08
Current Penalty 11154.0
Initial Penalty 11154.0
Final Order 2017-02-24
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) For the construction site, as observed on or about 11/18/2017, employees working on the roof of a residence were exposed to a fall hazards of at least 9 feet and 4 inches. The employees were not using fall protection systems. The AA Contracting Services, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (1926.501(b)(13), which was contained in OSHA inspection number 1156124, citation number 1 , item number 2b and was affirmed as a final order on 06/29/2016, with respect to a workplace located at Lot # 58 Whirlaway Drive in Davenport, FL.
Citation ID 02001
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2017-01-27
Abatement Due Date 2017-02-23
Current Penalty 5577.0
Initial Penalty 5577.0
Final Order 2017-02-24
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: (a) For the construction site, as observed on or about 11/18/2017 employees working on the roof of a residence were exposed to a fall hazards of at least 9 feet and 4 inches.
341906907 0420600 2016-11-10 4724 SLEEPY HOLLOW DR., KISSIMMEE, FL, 34747
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2016-11-10
Case Closed 2020-04-15

Related Activity

Type Inspection
Activity Nr 1190709
Safety Yes
Type Referral
Activity Nr 1154265
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2016-12-20
Abatement Due Date 2017-01-03
Current Penalty 2138.0
Initial Penalty 2138.0
Final Order 2017-01-18
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) For the construction site, as occurring on or about 11/07/2016, employees used the top step of a step ladder as a step. On 11/07/2016, an employee fell off of a step ladder after the ladder was struck by a wall sustaining injuries and was hospitalized.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B15
Issuance Date 2016-12-20
Abatement Due Date 2017-01-03
Current Penalty 2138.0
Initial Penalty 2138.0
Final Order 2017-01-18
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: a) For the construction site, as observed on or about 11/16/2016, ladders were not being inspected on a periodic basis to identify safety hazards. They were allowed to be damaged to the point where they started to shake when employees were on them.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2016-12-20
Abatement Due Date 2017-01-10
Current Penalty 2138.0
Initial Penalty 2138.0
Final Order 2017-01-18
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. a) For the residential construction site, as observed on or about 11/16/2016, employees using step ladders had not received any ladder safety training and were not able to recognize hazards related to ladders.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19261425 C03
Issuance Date 2016-12-20
Abatement Due Date 2017-01-10
Current Penalty 2138.0
Initial Penalty 2138.0
Final Order 2017-01-18
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1425(c)(3): The materials were not rigged by a qualified rigger. a) For the residential construction site, as discovered on or about 11/16/2016, employees who had conducted rigging of framed walls on site had not received rigging training and were not qualified riggers.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261430 D
Issuance Date 2016-12-20
Abatement Due Date 2017-01-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-01-18
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1430(d): The employer did not train each competent person and each qualified person regarding the requirements of this subpart applicable to their respective roles. a) For the residential construction site, as discovered on or about 11/16/2016, employees engaged in rigging work were not trained as qualified riggers in the requirements of this subpart.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19261428 A
Issuance Date 2016-12-20
Abatement Due Date 2017-01-03
Current Penalty 2138.0
Initial Penalty 2138.0
Final Order 2017-01-18
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1428(a): The employer of the signal person did not ensure that each signal person met the Qualifications Requirements (paragraph (c) of this section) prior to giving any signals: a) For the construction site, as occurring on or about 11/07/2016, employees giving signals to cranes were not qualified in the right type of signals and had not received any signal training meeting the requirements of 1926.1428(c). On 11/07/2016, while giving signals to a crane operator, the load wall being lifted struck the ladder an employee was on resulting in the employee's hospitalization.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19261430 B
Issuance Date 2016-12-20
Abatement Due Date 2017-01-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-01-18
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1430(b): The employer did not train employees in the signal qualifications. a) For the construction site, as occurring on or about 11/07/2016, employees were not trained in giving signals to cranes by their employer. On 11/07/2016, while giving signals to a crane operator, the load wall being lifted struck the ladder an employee was on resulting in the employee's hospitalization.
341561249 0420600 2016-06-20 LOT #58 WHIRLAWAY DR, DAVENPORT, FL, 33837
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-06-20
Emphasis L: FALL, P: FALL
Case Closed 2016-08-11

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2016-06-23
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2016-06-29
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. At the north side of the building, employees were exposed to a 14 foot fall hazard during stucco work, in that, a 42 inch wide scaffold had a single prefabricated metal platform 20 inches wide used as a working platform, on or about 06/20/2016.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2016-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-29
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a. At the north side of the building, employees were exposed to a 14 foot fall hazard during stucco work, in that, a single plank was used to bridge both sides of the scaffold to the roof to access the exterior walls of the second floor, on or about 06/20/2016.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2016-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-29
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): Portable ladder, hook-on ladder, attachable ladder, stair tower, stairway-type ladder, ramp, runway, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used to access scaffold platform more than 2 feet above or below a point of access: a. At the north side of the building, employees were exposed to a 14 foot fall hazard during stucco work, in that, a safe access was not provided and employees were climbing the end frames to gain access to the scaffold, on or about 06/20/2016.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2016-06-23
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2016-06-29
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. At the north side of the building, employees were exposed to a 14 foot fall hazard during stucco work, in that, a tubular welded frame scaffold two frames high and two frames wide was used without guardrails on the top working platforms, on or about 06/20/2016.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2016-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-29
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. At the north side of the building, an employee was exposed to a 10 foot fall hazard while on the roof of the first floor during stucco work at the exterior walls of the second floor, on or about 06/20/2016.
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2016-06-23
Abatement Due Date 2016-08-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-29
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): A safety and health program was not initiated and/or maintained to provide compliance with the general safety and health provisions of the standard: a. The employer did not develop and implement a safety and health program to address the company policy on safety as well as the employer/employee responsibilities.

Date of last update: 02 Apr 2025