Search icon

THREE BROTHERS CONCRETE INC - Florida Company Profile

Company Details

Entity Name: THREE BROTHERS CONCRETE INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation

THREE BROTHERS CONCRETE INC is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock.
In Florida, Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 25 Apr 2016 (9 years ago)
Document Number: P16000036804
FEI/EIN Number 81-2409294

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 5724 mckinley st, hollywood, FL 33021
Mail Address: 5724 mckinley st, hollywood, FL 33021
ZIP code: 33021
County: Broward
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
GONZALEZ, FRANCISCO Agent 5724 mckinley st, hollywood, FL 33021
GONZALEZ, FRANCISCO President 5724 mckinley st, hollywood, FL 33021

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2023-04-25 5724 mckinley st, hollywood, FL 33021 -
CHANGE OF MAILING ADDRESS 2023-04-25 5724 mckinley st, hollywood, FL 33021 -
REGISTERED AGENT ADDRESS CHANGED 2023-04-25 5724 mckinley st, hollywood, FL 33021 -

Documents

Name Date
ANNUAL REPORT 2024-04-19
ANNUAL REPORT 2023-04-25
ANNUAL REPORT 2022-03-08
ANNUAL REPORT 2021-04-22
ANNUAL REPORT 2020-03-27
ANNUAL REPORT 2019-03-18
ANNUAL REPORT 2018-01-20
ANNUAL REPORT 2017-01-24
Domestic Profit 2016-04-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346067077 0418800 2022-07-08 13030 ADDILYN CT LOT #2, DAVIE, FL, 33325
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-07-08
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2023-01-03
Abatement Due Date 2023-01-30
Current Penalty 5801.0
Initial Penalty 5801.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: A) On or about July 6, 2022, at 13050 Addilyn Ct., Lot #3, Davie, Florida, employees were exposed to a fall height of approximately 13 feet to ground level when applying plastering to the walls of a home under construction when using a scaffold without a safe means of access and egress; the employees used the crossbraces to access/egress the scaffold. B) On or about July 7, 2022, at 13050 Addilyn Ct., Lot #8, Davie, Florida, employees were exposed to a fall height of approximately 13 feet to ground level when applying plastering to the walls of a home under construction when using a scaffold without a safe means of access and egress; the employees used the crossbraces to access/egress the scaffold. C) On or about July 8, 2022, at 13050 Addilyn Ct., Lot #2, Davie, Florida, employees were exposed to a fall height of approximately 13 feet to ground level when applying plastering to the walls of a home under construction when using a scaffold without a safe means of access and egress; the employees used the crossbraces to access/egress the scaffold.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260451 G01 VII
Issuance Date 2023-01-03
Abatement Due Date 2023-01-30
Current Penalty 58011.0
Initial Penalty 58011.0
Final Order 2023-05-03
Nr Instances 3
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: A) On or about July 6, 2022, at 13050 Addilyn Ct, Lot #3, Davie, Florida, employees were exposed to a fall height of approximately 13 feet to ground level when applying plastering to the walls of a home under construction while not utilizing guardrails and/or any other means of fall protection. B) On or about July 7, 2022, at 13050 Addilyn Ct, Lot #8, Davie, Florida, employees were exposed to a fall height of approximately 13 feet to ground level when applying plastering to the walls of a home under construction while not utilizing guardrails and/or any other means of fall protection. C) On or about July 8, 2022, at 13050 Addilyn Ct, Lot #2, Davie, Florida, employees were exposed to a fall height of approximately 13 feet to ground level when applying plastering to the walls of a home under construction while not utilizing guardrails and/or any other means of fall protection.
Citation ID 02002
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2023-01-03
Abatement Due Date 2023-01-23
Current Penalty 58011.0
Initial Penalty 58011.0
Final Order 2023-05-03
Nr Instances 3
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): A) On or about July 6, 2022, at 13050 Addilyn Ct, Lot #3, Davie, FL 33325, employees were exposed to a fall height of up to 13 feet to ground level when plastering the wall of a two-story residential home while not utilizing a personal fall arrest system nor were they provided with an alternative fall protection system. B) On or about July 7, 2022, at 13050 Addilyn Ct, Lot #8, Davie, FL 33325, employees were exposed to a fall height of up to 13 feet to ground level when plastering the wall of a two-story residential home while not utilizing a personal fall arrest system nor were they provided with an alternative fall protection system. B) On or about July 8, 2022, at 13050 Addilyn Ct, Lot #2, Davie, FL 33325, employees were exposed to a fall height of up to 13 feet to ground level when plastering the wall of a two-story residential home while not utilizing a personal fall arrest system nor were they provided with an alternative fall protection system.
346067002 0418800 2022-06-29 13090 ADDILYN CT LOT #5, DAVIE, FL, 33325
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-06-29
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2022-12-28
Abatement Due Date 2023-01-25
Current Penalty 4351.0
Initial Penalty 4351.0
Final Order 2023-07-28
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about June 29, 2022, at 13050 Addilyn Ct, Lot #5, Davie, Florida, employees were exposed to a fall height of approximately 13 feet to ground level when applying plastering to the walls of a home under construction while not utilizing guardrails and/or any other means of fall protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2022-12-28
Abatement Due Date 2023-01-25
Current Penalty 4351.0
Initial Penalty 4351.0
Final Order 2023-07-28
Nr Instances 1
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about June 29, 2022, at 13050 Addilyn Ct., Lot #5, Davie, Florida, employees were exposed to a fall height of approximately 13 feet to ground level when applying plastering to the walls of a home under construction when using a scaffold without a safe means of access and egress; the employees used the crossbraces to access/egress the scaffold.