344176904
|
0418800
|
2019-07-24
|
13890 NE 3RD CRT. #418, NORTH MIAMI, FL, 33161
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-07-24
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2021-09-28
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 I |
Issuance Date |
2019-08-16 |
Abatement Due Date |
2019-08-28 |
Current Penalty |
1140.0 |
Initial Penalty |
2273.0 |
Final Order |
2019-09-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: On or about July 24, 2019, on the side of the building, an employee worked from a two-tier tubular scaffold that was not fully planked, exposing the employee to a fall hazard of approximately 14 feet. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2019-08-16 |
Abatement Due Date |
2019-08-28 |
Current Penalty |
1140.0 |
Initial Penalty |
2273.0 |
Final Order |
2019-09-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about July 24, 2019, on the side of the building, employees were accessing the one tier tubular welded scaffold approximately 14 feet high by climbing the outside rails and not utilizing a ladder, exposing the employees to a fall hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2019-08-16 |
Abatement Due Date |
2019-08-28 |
Current Penalty |
1140.0 |
Initial Penalty |
2273.0 |
Final Order |
2019-09-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about July 24, 2019, on the side of the building, an employee worked from a two-tier tubular scaffold without fall protection, exposing the employee to a fall hazard of approximately 14 feet. |
|
|
343988101
|
0418800
|
2019-05-07
|
5288 ALTON RD., MIAMI BEACH, FL, 33140
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-05-07
|
Emphasis |
L: FALL
|
Case Closed |
2021-09-28
|
Related Activity
Type |
Inspection |
Activity Nr |
1402637 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1398802 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2019-11-06 |
Abatement Due Date |
2019-11-19 |
Current Penalty |
1421.0 |
Initial Penalty |
2842.0 |
Final Order |
2019-11-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about May 7, 2019, on the third tier in the West side of the building at 5288 Alton Rd. Miami Beach, Florida, 33140, an employee was working from a scaffold that was not fully plank at a height of approximately 24 feet above ground level, exposed to a fall hazard. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2019-11-06 |
Abatement Due Date |
2019-11-19 |
Current Penalty |
1421.0 |
Initial Penalty |
2842.0 |
Final Order |
2019-11-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: Such activities were not performed only by experienced and trained employees selected for such work by the competent person: On or about May 7, 2019, an employee working from scaffolding located on 5288 Alton Road in Miami Beach, Florida, was exposed to a 24-foot fall hazard while working from a scaffold that was not erected by a competent person. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260454 B |
Issuance Date |
2019-11-06 |
Abatement Due Date |
2019-11-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-11-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: On or about May 7, 2019, an employee working from scaffolding located on 5288 Alton Road in Miami Beach, Florida, was exposed to a 24-foot fall hazard while working from a scaffold that was not erected by a person trained as a scaffold competent person. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2019-11-06 |
Abatement Due Date |
2019-11-19 |
Current Penalty |
1421.0 |
Initial Penalty |
2842.0 |
Final Order |
2019-11-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about May 7, 2019, on the third tier in the West side of the building 5288 Alton Road in Miami Beach, an employee was engaged in plastering work from a scaffold without a guardrail system at a height of approximately 24 feet above ground level, exposing the employee to a fall hazard. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2019-11-06 |
Abatement Due Date |
2019-11-29 |
Current Penalty |
2001.0 |
Initial Penalty |
3978.0 |
Final Order |
2019-11-26 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about May 7, 2019, on the third tier in the East side of the building,at 5288 Alton Rd. Miami Beach, Florida, 33140, employees were engaged in plastering work from a roof at a height of approximately 24 feet above ground level, exposing the employees to a fall hazard. |
|
|