Search icon

COSMOR CONSTRUCTION, CORP

Company Details

Entity Name: COSMOR CONSTRUCTION, CORP
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Active
Date Filed: 04 Apr 2016 (9 years ago)
Document Number: P16000030415
FEI/EIN Number 35-2558706
Address: 7800 TURKEY OAK LN, KISSIMMEE, FL 34747
Mail Address: 7800 Turkey Oak Ln, KISSIMMEE, FL 34747
ZIP code: 34747
County: Osceola
Place of Formation: FLORIDA

Agent

Name Role Address
DIAS PEREIRA, MARCO AURELIO Agent 7800 Turkey Oak Ln, Kissimmee, FL 34747

President

Name Role Address
DIAS PEREIRA, MARCO AURELIO President 7800 Turkey oak Ln, Kissimmee, FL 34747

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2021-03-30 7800 TURKEY OAK LN, KISSIMMEE, FL 34747 No data
CHANGE OF MAILING ADDRESS 2021-03-30 7800 TURKEY OAK LN, KISSIMMEE, FL 34747 No data
REGISTERED AGENT ADDRESS CHANGED 2021-03-30 7800 Turkey Oak Ln, Kissimmee, FL 34747 No data

Documents

Name Date
ANNUAL REPORT 2024-03-20
ANNUAL REPORT 2023-03-28
ANNUAL REPORT 2022-04-26
ANNUAL REPORT 2021-03-30
ANNUAL REPORT 2020-05-06
ANNUAL REPORT 2019-04-10
ANNUAL REPORT 2018-04-11
ANNUAL REPORT 2017-04-25
Domestic Profit 2016-04-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346614134 0419730 2023-04-05 8186 SAYINGS DR., WINTER GARDEN, FL, 34787
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2023-04-05
Emphasis L: FALL

Related Activity

Type Referral
Activity Nr 2018984
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-08-03
Abatement Due Date 2023-08-22
Current Penalty 1707.99
Initial Penalty 3349.0
Final Order 2023-09-19
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Jobsite: 8186 Sayings Dr. Winter Garden, FL 34787, Cosmor Construction Corp. did not provide fall protection while employees were installing gutters on a (10) feet high roof, exposing employees to fall hazards, on or about 04/05/2023.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2023-08-03
Abatement Due Date 2023-08-22
Current Penalty 1707.99
Initial Penalty 3349.0
Final Order 2023-09-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) Jobsite: 8186 Sayings Dr. Winter Garden, FL 34787. Cosmor Construction Corp.'s ladder was extended approximately (2) feet past the roof landing, while being used to gain access to install gutters on the roof, approximately (10) feet high, , exposing employees to fall hazards, on or about 04/05/2023.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2023-08-03
Abatement Due Date 2023-09-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-09-19
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. (a) Jobsite: 8186 Sayings Dr. Winter Garden, FL 34787. Cosmor Construction Corp. did not provide a training program for each employee installing gutters 10 feet high, exposing employees to fall hazards, on or about 04/05/2023.
Citation ID 02002
Citaton Type Other
Standard Cited 19261060 A
Issuance Date 2023-08-03
Abatement Due Date 2023-09-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-09-19
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a):The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. (a) Jobsite: 8186 Sayings Dr. Winter Garden, FL 34787. Cosmor Construction Corp. did not provide a ladder training program for employee using a ladder to access a 10 foot roof to install gutters, exposing employees to fall hazards, on or about 04/05/2023.

Date of last update: 19 Feb 2025

Sources: Florida Department of State