Search icon

RAMON'S QUALITY PAINTING INC - Florida Company Profile

Company Details

Entity Name: RAMON'S QUALITY PAINTING INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

RAMON'S QUALITY PAINTING INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 24 Mar 2016 (9 years ago)
Date of dissolution: 22 Sep 2017 (8 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 22 Sep 2017 (8 years ago)
Document Number: P16000027677
Address: 36 WEST ANN CIRCLE, SANTA ROSA BEACH, FL, 32459
Mail Address: 36 WEST ANN CIRCLE, SANTA ROSA BEACH, FL, 32459
ZIP code: 32459
County: Walton
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MICHUA RAMIRO President 36 WEST ANN STREET, SANTA ROSA BEACH, FL, 32459
MICHUA RAMIRO Agent 36 WEST ANN STREET, SANTA ROSA BEACH, FL, 32459

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2017-09-22 - -

Documents

Name Date
Domestic Profit 2016-03-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342029592 0419700 2017-01-17 11394 US HIGHWAY 98, DESTIN, FL, 32550
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2017-01-17
Emphasis L: FALL, P: FALL
Case Closed 2020-10-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01 I
Issuance Date 2017-01-23
Current Penalty 3803.0
Initial Penalty 3803.0
Final Order 2017-02-17
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a. On or about January 17, 2017, on a ladder jack scaffold system, two employees performing painting operations were not protected from a 17-foot 4-inch fall hazard by use of a fall protection system.