Search icon

PENA'S GENERAL CONSTRUCTION SERVICES, INC. - Florida Company Profile

Company Details

Entity Name: PENA'S GENERAL CONSTRUCTION SERVICES, INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

PENA'S GENERAL CONSTRUCTION SERVICES, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 23 Feb 2016 (9 years ago)
Date of dissolution: 23 Sep 2022 (3 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2022 (3 years ago)
Document Number: P16000017795
FEI/EIN Number 81-1622932

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 975 11TH ST SW, VERO BEACH, FL, 32962, US
Mail Address: 975 11TH ST SW, VERO BEACH, FL, 32962, US
ZIP code: 32962
County: Indian River
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
PENA EFRAIN President 975 11TH ST SW, VERO BEACH, FL, 32962
PENA EFRAIN Agent 975 11TH ST SW, VERO BEACH, FL, 32962

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2025-11-01 975 11TH ST SW, VERO BEACH, FL 32962 -
CHANGE OF MAILING ADDRESS 2025-11-01 975 11TH ST SW, VERO BEACH, FL 32962 -
CHANGE OF PRINCIPAL ADDRESS 2024-11-01 975 11TH ST SW, VERO BEACH, FL 32962 -
CHANGE OF MAILING ADDRESS 2024-11-01 975 11TH ST SW, VERO BEACH, FL 32962 -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2022-09-23 - -
REGISTERED AGENT NAME CHANGED 2021-11-05 PENA, EFRAIN -
REINSTATEMENT 2021-11-05 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2021-09-24 - -
AMENDMENT 2016-08-15 - -

Debts

Document Number Status Case Number Name of Court Date of Entry Expiration Date Amount Due Plaintiff
J23000547638 ACTIVE 17-315-D2 LEON COUNTY 2023-01-25 2028-11-15 $5,035.73 DFS DIVISION OF WORKERS COMPENSATION, 200 EAST GAINES STREET, TALLAHASSEE, FL 32399-4228

Documents

Name Date
REINSTATEMENT 2021-11-05
ANNUAL REPORT 2020-03-13
ANNUAL REPORT 2019-02-18
ANNUAL REPORT 2018-03-07
ANNUAL REPORT 2017-03-27
Amendment 2016-08-15
Domestic Profit 2016-02-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345700496 0418800 2021-12-22 4601 SW MANSFIELD ST., PORT SAINT LUCIE, FL, 34953
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-12-22
Emphasis L: FALL, P: FALL
Case Closed 2023-03-16

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2021-12-30
Current Penalty 3283.0
Initial Penalty 3283.0
Final Order 2022-01-31
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. On or about December 22, 2021, at a new residential construction located at 4601 SW Mainsfield, Port Saint Lucie, FL, 34953, employees were exposed to struck-by hazard while flying trusses without using any means of head protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2021-12-30
Current Penalty 3283.0
Initial Penalty 3283.0
Final Order 2022-01-31
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about December 22, 2021, at a new residential construction located at 4601 SW Mainsfield, Port Saint Lucie, FL, 34953, employees were exposed to approximately an 8-foot fall hazard while installing trusses without using any means of conventional fall protection system.
342034410 0418800 2017-01-18 3396 SW GATLIN BLVD, PORT SAINT LUCIE, FL, 34953
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-01-18
Emphasis P: FALL, L: FALL, N: SILICA
Case Closed 2018-08-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2017-02-13
Abatement Due Date 2017-03-27
Current Penalty 815.0
Initial Penalty 1630.0
Final Order 2017-03-13
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: On or about January 18, 2017 at the above addressed job site, employees performing block laying operation were not provided with gloves, exposing them to come in contact with Portland cement (Florida super masonry type S) that causes skin irritation and dermatitis.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B01 II
Issuance Date 2017-02-13
Abatement Due Date 2017-03-27
Current Penalty 1087.0
Initial Penalty 2173.0
Final Order 2017-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): On or about January 18, 2017 at the above address employees were exposed to hall hazard while working form a scaffold not fully planked.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 B10
Issuance Date 2017-02-13
Abatement Due Date 2017-03-27
Current Penalty 1087.0
Initial Penalty 2173.0
Final Order 2017-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(10): Scaffold components manufactured by different manufacturers were intermixed such that the components fit together with force and the scaffold's structural integrity was not maintained by the user: On or about January 18, 2017 employees were working from a scaffold that was assembled with components manufactured by different manufacturers and held together by chicken wire.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2017-02-13
Abatement Due Date 2017-03-27
Current Penalty 1087.0
Initial Penalty 2173.0
Final Order 2017-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about January 18, 2017 employees were working from a scaffold that was missing base plates and supported on blocks.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 G01 VI
Issuance Date 2017-02-13
Abatement Due Date 2017-03-27
Current Penalty 1087.0
Initial Penalty 2173.0
Final Order 2017-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold was not protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity): On or about January 18, 2017 employees were working from a 10- foot scaffold that was missing fall arrest system or guardrail system.
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 K06
Issuance Date 2017-02-13
Abatement Due Date 2017-03-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-03-13
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: On or about January 18, 2017 at the above addressed worksite, the employer did not provide employees that voluntarily wear 3M 8110S N95 Filtering Facepiece Respirators with the information contained in Appendix D of 29 CFR 1910.134.
Citation ID 02002
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2017-02-13
Abatement Due Date 2017-03-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-03-13
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): On or about January 18, 2017 at the above addressed job site, the employer did not develop and implement a written hazard communication program describing hazardous chemicals, such as but not limited to Portland cement (Titan America Portland cement), for employees performing block laying work.

Date of last update: 02 Apr 2025