Search icon

IDV CONSTRUCTION INC - Florida Company Profile

Company Details

Entity Name: IDV CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

IDV CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 19 Jan 2016 (9 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: P16000006528
FEI/EIN Number 811218426

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3840 VALENCIA AVE, MULBERRY, FL, 33860, US
Mail Address: 3840 VALENCIA AVE, MULBERRY, FL, 33860, US
ZIP code: 33860
County: Polk
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
DIAZ JORGE President 3840 VALENCIA AVE, MULBERRY, FL, 33860
DIAZ JORGE Agent 3840 VALENCIA AVE, MULBERRY, FL, 33860

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
CHANGE OF PRINCIPAL ADDRESS 2018-04-25 3840 VALENCIA AVE, MULBERRY, FL 33860 -
CHANGE OF MAILING ADDRESS 2018-04-25 3840 VALENCIA AVE, MULBERRY, FL 33860 -
REGISTERED AGENT ADDRESS CHANGED 2018-04-25 3840 VALENCIA AVE, MULBERRY, FL 33860 -

Court Cases

Title Case Number Docket Date Status
Bridgehaven at Citrus Park Homeowners Association, Inc., Petitioner(s) v. Brad McDonald Roofing & Construction, Inc., Quality Built, LLC, SMC Systems, Inc. d/b/a Skye Tec n/k/a SMC Systems, LLC, BDH Consulting, LLC, GMG Flooring, LLC d/b/a Wrap Quest, Sutton Contracting Solutions, Inc., Roland's Painting Services, Harold Clayton Painting, Inc. n/k/a EX-HCP, Inc., et al., Respondent(s). 2D2024-2458 2024-10-23 Open
Classification Original Proceedings - Circuit Civil - Certiorari
Court 2nd District Court of Appeal
Originating Court Circuit Court for the Thirteenth Judicial Circuit, Hillsborough County
24-CA-002624

Parties

Name BRAD MCDONALD ROOFING & CONSTRUCTION, INC.
Role Respondent
Status Active
Representations Charles Eric Bearden
Name QUALITY BUILT, LLC
Role Respondent
Status Active
Representations Bruce Robert Calderon, Jana Marie Fried
Name SMC SYSTEMS, INC.
Role Respondent
Status Active
Representations Bruce Robert Calderon, Jana Marie Fried, Crystal Leah Arocha
Name d/b/a Skye Tec
Role Respondent
Status Active
Representations Bruce Robert Calderon, Jana Marie Fried
Name n/k/a SMC Systems, LLC
Role Respondent
Status Active
Representations Bruce Robert Calderon, Jana Marie Fried
Name BDH CONSULTING, LLC
Role Respondent
Status Active
Representations Edward M. Baird, Travis William Fulford
Name GMG FLOORING, LLC
Role Respondent
Status Active
Representations Michael Keegan Kiernan, Frank Edward Dylong, Jr., Kimberly Tudor Van Der Riet
Name d/b/a Wrap Quest
Role Respondent
Status Active
Representations Michael Keegan Kiernan, Frank Edward Dylong, Jr., Kimberly Tudor Van Der Riet
Name SUTTON CONTRACTING SOLUTIONS, INC.
Role Respondent
Status Active
Representations Gerald C. Biondi
Name ROLAND'S PAINTING SERVICES INC.
Role Respondent
Status Active
Representations Kimberly E. Young, Tyler Allen Cooney
Name n/k/a EX-HCP, Inc.
Role Respondent
Status Active
Representations Matthew Bernstein
Name C & C WINDOW & DOOR COMPANY, INC.
Role Respondent
Status Active
Representations Timothy Russell Moorhead, Jessica Anne Lee
Name Faith Plastering and Stucco, Inc.
Role Respondent
Status Active
Representations Christina Bredahl Gierke, Kyle Matthew Costello
Name IDEAL SERVICES OF TAMPA INC.
Role Respondent
Status Active
Representations Kory J. Ickler, Christopher Ian Hall
Name C. STERLING QUALITY ROOFING, INC.
Role Respondent
Status Active
Representations Robert Nathan Johnson, Rinaldo J. Cartaya, III
Name MARIACHI FRAMING INC.
Role Respondent
Status Active
Representations Julius E. Adams
Name RANEY CONSTRUCTION, INC.
Role Respondent
Status Active
Representations Bryan Marc Krasinski
Name n/k/a ACR Family Construction, Inc.
Role Respondent
Status Active
Representations Bryan Marc Krasinski
Name IDV CONSTRUCTION INC
Role Respondent
Status Active
Representations Douglas Ivan Wall
Name Hon. Darren David Farfante
Role Judge/Judicial Officer
Status Active
Name Hillsborough Clerk
Role Lower Tribunal Clerk
Status Active
Name BRIDGEHAVEN AT CITRUS PARK HOMEOWNERS ASSOCIATION, INC.
Role Petitioner
Status Active
Representations Samuel Robert Alexander, Bradley Mathew Beall, Nicholas B. Vargo, Brian Curtis Tannenbaum, Stephen M. Hauptman, Phillip Edmund Joseph, Evan Jonathan Small, Brian Thomas Crevasse
Name Harold Clayton Painting, Inc.
Role Respondent
Status Active
Representations Kenneth E. Amos, Jr., Kimble David McKay, Jasmine Monique Petrishin
Name 84 LUMBER COMPANY
Role Respondent
Status Active
Representations Hardy L. Roberts, III, Mark Smith, Kelly Carey Bagge, James M. Barlow, Jr.

Docket Entries

Docket Date 2024-11-22
Type Record
Subtype Appendix to Reply
Description Appendix to Reply Brief
On Behalf Of Brad McDonald Roofing & Construction, Inc.
Docket Date 2024-11-22
Type Response
Subtype Reply to Response
Description Reply to Response
On Behalf Of Brad McDonald Roofing & Construction, Inc.
View View File
Docket Date 2024-11-21
Type Response
Subtype Response
Description RESPONSE TO PETITION FOR WRIT OF CERTIORARI
On Behalf Of SMC Systems, Inc.
Docket Date 2024-10-23
Type Miscellaneous Document
Subtype Pay Case Filing Fee-300
Description Pay Case Filing Fee-300
On Behalf Of Bridgehaven at Citrus Park Homeowners Association, Inc.
View View File
Docket Date 2024-10-23
Type Order
Subtype Order on Filing Fee
Description This petition has been filed without a filing fee required by section 35.22(2)(a), Florida Statutes. Counsel for Petitioner shall forward the required $300.00 filing fee or, if applicable, an affidavit of insolvency in conformity with the requirements of chapter 57, Florida Statutes, to this court within twenty days from the date of this order. If this court does not receive either of the above within the prescribed time, this petition may be subject to dismissal without further notice.
View View File
Docket Date 2024-10-23
Type Letter
Subtype Acknowledgment Letter
Description Acknowledgment Letter
View View File
Docket Date 2024-10-23
Type Record
Subtype Appendix to Petition
Description Appendix to Petition
On Behalf Of Bridgehaven at Citrus Park Homeowners Association, Inc.
Docket Date 2024-10-23
Type Petition
Subtype Petition Certiorari
Description Petition Certiorari
On Behalf Of Bridgehaven at Citrus Park Homeowners Association, Inc.
Docket Date 2024-12-31
Type Order
Subtype Order on Motion for Extension of Time to Reply to Response
Description Petitioner's motion for extension of time to serve the reply is granted. The reply shall be served within 30 days. However, further requests for extension of time are unlikely to receive favorable consideration.
View View File
Docket Date 2024-12-23
Type Notice
Subtype Notice of Joinder in Filing
Description HAROLD CLAYTON PAINTING, INC. N/K/A EX-HCP, INC.'S NOTICE OF FORMAL ADOPTION OF SMC SYSTEM, INC. D/B/A SKYE TEC N/K/A SMC SYSTEMS, LLC AND QUALITY BUILT, LLC'S AND BRAD MCDNOALD ROOFING & CONSTRUCTION, INC.'S RESPONSES TO CONSOLIDATED PETITIONS FOR WRIT OF CERTERIORATI
On Behalf Of n/k/a EX-HCP, Inc.
Docket Date 2024-12-20
Type Motions Extensions
Subtype Motion for Extension of Time to Serve Reply Brief
Description Motion for Extension of Time to Serve Reply Brief
On Behalf Of Bridgehaven at Citrus Park Homeowners Association, Inc.
Docket Date 2024-12-13
Type Notice
Subtype Notice of Appearance
Description Notice of Appearance
On Behalf Of n/k/a EX-HCP, Inc.
Docket Date 2024-11-22
Type Notice
Subtype Notice of Joinder in Filing
Description Notice of Joinder in Filing - ROLAND'S PAINTING SERVICES, INC.'S NOTICE OF FORMAL ADOPTION OF SMC SYSTEMS, INC. D/B/A SKYE TEC N/K/A SMC SYSTEMS, LLC AND QUALITY BUILT, LLC'S RESPONSE TO PETITION FOR WRIT OF CERTIORAR
On Behalf Of Roland's Painting Services
Docket Date 2024-10-24
Type Order
Subtype Order to Respond to Petition
Description Respondent shall serve a response to the Petition for Writ of Certiorari within thirty days from the date of this order. Petitioner may serve a reply within thirty days thereafter. The parties shall keep this court apprised of all hearings or trial dates that may affect this proceeding.
View View File

Documents

Name Date
ANNUAL REPORT 2018-04-25
ANNUAL REPORT 2017-01-09
Domestic Profit 2016-01-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343866117 0420600 2019-03-21 18229 LEAFMORE ST., LUTZ, FL, 33548
Inspection Type FollowUp
Scope NoInspection
Safety/Health Safety
Close Conference 2019-03-21
Case Closed 2019-04-05

Related Activity

Type Inspection
Activity Nr 1335799
Safety Yes
343357992 0420600 2018-07-31 18229 LEAFMORE STREET, LUTZ, FL, 33548
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-07-31
Emphasis L: FALL, P: FALL
Case Closed 2020-10-02

Related Activity

Type Inspection
Activity Nr 1335896
Safety Yes
Type Inspection
Activity Nr 1335879
Safety Yes
Type Inspection
Activity Nr 1335953
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2018-10-11
Abatement Due Date 2018-11-06
Current Penalty 3326.0
Initial Penalty 3326.0
Final Order 2018-11-06
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) On or about July 31, 2018 at the job-site located at 18229 Leafmore Street, Lutz (FL); three employees using pneumatic staple guns while installing water resistant barrier and lath beads were not wearing eye protection, exposing to struck-by hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2018-10-11
Abatement Due Date 2018-11-06
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2018-11-06
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On or about July 31, 2018 at the job-site located at 18229 Leafmore Street, Lutz (FL), an employee was installing water resistant barrier and lath beads while standing on the north side veranda roof, exposed to a 12 foot fall hazard. b) On or about July 31, 2018 at the job-site located at 18229 Leafmore Street, Lutz (FL), an employee was installing water resistant barrier and lath beads while standing on the south side garage roof, exposed to a 12 foot fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2018-10-11
Abatement Due Date 2018-11-06
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2018-11-06
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about July 31, 2018 at the job-site located at 18229 Leafmore Street, Lutz (FL), an employee was installing water resistant barrier and lath beads while using a stepladder folded against the wall to access the 20 foot wall edge, exposing to a 16 foot fall hazard.
343310819 0420600 2018-07-16 5004 N US HIGHWAY 41, RUSKIN, FL, 33570
Inspection Type Planned
Scope Partial
Safety/Health Safety
Emphasis L: FALL, P: FALL
Case Closed 2020-10-02

Related Activity

Type Inspection
Activity Nr 1331112
Safety Yes
Type Inspection
Activity Nr 1334960
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2018-10-18
Abatement Due Date 2018-11-14
Current Penalty 2217.0
Initial Penalty 2217.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On July 16, 2018, at the east side of the commercial building; for employees handling hazardous materials such as but not limited to stucco cement.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19101200 G01
Issuance Date 2018-10-18
Abatement Due Date 2018-11-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use. a) On or about July 16, 2018, at the east side of the commercial building; for hazardous materials such as but not limited to stucco cement.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2018-10-18
Abatement Due Date 2018-11-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) a) On or about July 16, 2018, at the east side of the commercial building; for employees handling hazardous materials such as but not limited to stucco cement.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2018-10-18
Abatement Due Date 2018-11-14
Current Penalty 2217.0
Initial Penalty 2217.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On or about July 16, 2018, at the east side of the commercial building; seven employees who were exposed to flying debris while plastering the exterior wall and mixing stucco cement were not wearing eye protection.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2018-10-18
Abatement Due Date 2018-11-14
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) On or about July 16, 2018, at the east side of the commercial building, the tubular framed scaffolding system 3 tiers high being used by employees plastering stucco was missing mudsills in all frames, exposing employees to fall, collapse and struck by hazards.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2018-10-18
Abatement Due Date 2018-11-14
Current Penalty 2217.0
Initial Penalty 2217.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. a) On or about July 16, 2018, at the east side of the commercial building, the north end of the third level of the supported scaffold used by employees to plaster stucco on the wall had no guardrail system installed, exposing the employees to a 6 foot fall hazard.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260451 G04 XV
Issuance Date 2018-10-18
Abatement Due Date 2018-11-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(xv): Crossbracing used in place of a midrail was unacceptable because the crossing point of two braces is between 20 inches (0.5 m) and 30 inches ((0.8 M) above the work platform or as a top rail when the crossing point of two braces is not between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a top rail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The endpoints at each upright were more than 48 inches (1.3 m) apart. a) On or about July 16, 2018, at the east side of the commercial building, the second tier of supported scaffold used by employees to plaster stucco on the wall was missing guard rail components, exposing the employees to a 12 foot fall hazard.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2018-10-18
Abatement Due Date 2018-11-14
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a) On July 16, 2018, at the east side of the commercial building, employees plastering stucco were exposed to fall, collapse and struck by hazards, in that, the framed scaffolding system 3 tiers high by 4 columns across was missing cross bracing on the exterior side first level on the 1st, 2nd and 3rd columns, on the interior side on the first level 4th column and on the four columns on the 2nd and 3rd levels.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2018-10-18
Abatement Due Date 2018-11-14
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) On or about July 16, 2018, at the east side of the commercial building, employees working on a supported scaffold while plastering stucco on the exterior wall had not been trained on the hazards of the scaffolding system.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260451 B01
Issuance Date 2018-10-18
Current Penalty 7760.0
Initial Penalty 7760.0
Final Order 2018-11-14
Nr Instances 2
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) On or about July 16, 2018, at the east side of the commercial building, the third level of the supported scaffold used by employees to plaster stucco on the wall was not fully planked, exposing the employees to an 18 foot fall hazard. b) On or about July 16, 2018, at the east side of the commercial building, the second level of the supported scaffold used by employees to plaster stucco on the wall was not fully planked, exposing the employees to a 12 foot fall hazard. IDV Construction, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1257620, citation number 1, item number 1 and was affirmed as a final order on March 30, 2018, with respect to a workplace located at 4445 Casella Tampa, FL 33601.
Citation ID 02002
Citaton Type Repeat
Standard Cited 19260451 E01
Issuance Date 2018-10-18
Abatement Due Date 2018-11-14
Current Penalty 5543.0
Initial Penalty 5543.0
Final Order 2018-11-14
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) On or about July 16, 2018, at the east side of the commercial building, employees used the tubular components of the scaffold to access the three levels of the frame scaffold. IDV Construction, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1257620, citation number 1, item number 2 and was affirmed as a final order on March 30, 2018, with respect to a workplace located at 4445 Casella Tampa, FL 33601.
343164018 0420600 2018-05-16 4754 CLARK ROAD, SARASOTA, FL, 34233
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-05-16
Case Closed 2020-10-02

Related Activity

Type Referral
Activity Nr 1338621
Safety Yes
Type Inspection
Activity Nr 1316410
Safety Yes
Type Inspection
Activity Nr 1316429
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C01 II
Issuance Date 2018-07-12
Abatement Due Date 2018-07-24
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2018-08-08
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(1)(ii): 29 CFR 1926.451(c)(1)(ii): Supported scaffolds with a height to base width ratio of more than four to one (4:1) were not restrained from tipping by installing guys, ties, and braces at each end of the scaffold and/or at horizontal intervals not to exceed 30 feet (9.1 m): a) On or about 05/15/2018, at 4754 Clark Ave., Sarasota, FL 34233, scaffolding was erected with a height to width ratio of approximately 5.7:1 and was not tied into the adjacent building structure. Employees working on the scaffold were exposed to hazards associated with the scaffold collapsing since it was not tied into the building structure.
342576204 0420600 2017-08-11 4445 CASELLA, TAMPA, FL, 33601
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-08-11
Emphasis L: FALL, P: FALL
Case Closed 2018-05-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2018-01-25
Current Penalty 2217.0
Initial Penalty 2217.0
Final Order 2018-03-30
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports (a) Back of house - employees were exposed to a fall hazard of up to 14 feet while doing stucco work from a scaffold that was not fully planked on the top and lower level, on or about 8/11/17.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2018-01-25
Current Penalty 2217.0
Initial Penalty 2217.0
Final Order 2018-03-30
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. (a) Back of house - employees were exposed to a fall hazard of up to 14 feet, in that there was no safe access. The employees were using the end frames and they were going from the top of the scaffold and climbing over the 2nd floor guardrail to access the 2nd floor of the house, on or about 8/11/17.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2018-01-25
Current Penalty 2217.0
Initial Penalty 2217.0
Final Order 2018-03-30
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Back of house - an employee was exposed to a fall of 14 feet while stuccoing a house from the fabricated frame scaffold tht did not have guardrails, on or about 8/11/17.

Date of last update: 03 Apr 2025