Entity Name: | VALLEJO AND SON CONSTRUCTION INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
VALLEJO AND SON CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 14 Jan 2016 (9 years ago) |
Date of dissolution: | 04 Oct 2018 (7 years ago) |
Last Event: | VOLUNTARY DISSOLUTION |
Event Date Filed: | 04 Oct 2018 (7 years ago) |
Document Number: | P16000005106 |
FEI/EIN Number |
81-1113541
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 5450 BRUCE B. DOWNS BLVD, WESLEY CHAPEL, FL, 33543, US |
Mail Address: | 5450 BRUCE B DOWNS BLVD, WESLEY CHAPEL, FL, 33543, US |
ZIP code: | 33543 |
County: | Pasco |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
VALLEJO ISAIAS | President | 5450 BRUCE B. DOWNS BLVD, WESLEY CHAPEL, FL, 33543 |
VALLEJO ISAIAS | Agent | 5450 BRUCE B. DOWNS BLVD, WESLEY CHAPEL, FL, 33543 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2018-10-04 | - | - |
REGISTERED AGENT NAME CHANGED | 2018-04-03 | VALLEJO, ISAIAS | - |
AMENDMENT | 2018-03-06 | - | - |
REGISTERED AGENT ADDRESS CHANGED | 2018-03-06 | 5450 BRUCE B. DOWNS BLVD, WESLEY CHAPEL, FL 33543 | - |
AMENDMENT | 2017-02-22 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2017-01-09 | 5450 BRUCE B. DOWNS BLVD, WESLEY CHAPEL, FL 33543 | - |
CHANGE OF MAILING ADDRESS | 2017-01-09 | 5450 BRUCE B. DOWNS BLVD, WESLEY CHAPEL, FL 33543 | - |
AMENDMENT | 2016-06-20 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2018-04-03 |
Amendment | 2018-03-06 |
Amendment | 2017-02-22 |
ANNUAL REPORT | 2017-01-09 |
Amendment | 2016-06-20 |
Off/Dir Resignation | 2016-06-02 |
Domestic Profit | 2016-01-14 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342931250 | 0420600 | 2018-01-31 | 12858 BURNS, ODESSA, FL, 33556 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2018-06-14 |
Current Penalty | 3880.0 |
Initial Penalty | 3880.0 |
Final Order | 2018-07-11 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) roof - employees are exposed to a fall of up to 19 feet while installing the plywood decking, on or about 1/31/18. b) roof - employees are exposed to a fall of up to 19 feet while installing the plywood decking, on or about 2/1/18. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2018-06-14 |
Abatement Due Date | 2018-08-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-07-11 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) roof - employees are exposed to a fall of up to 19 feet while installing the plywood decking. The employer did not provide fall protection training, on or about 1/31/18. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2018-06-14 |
Current Penalty | 1663.0 |
Initial Penalty | 1663.0 |
Final Order | 2018-07-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) front of the house - employees were exposed to a fall of 9 feet 4 inches, in that, the ladder that was used only extended approximately 1 foot above the landing, on or about 1/31/18. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19261060 A |
Issuance Date | 2018-06-14 |
Abatement Due Date | 2018-08-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-07-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. (a) front of the house - employees were exposed to a fall of 9 feet 4 inches, in that, the ladder that was used only extended approximately 1 foot above the landing. The employer did not train the employees, on or about 1/31/18. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260020 B01 |
Issuance Date | 2018-06-14 |
Abatement Due Date | 2018-08-01 |
Current Penalty | 1663.0 |
Initial Penalty | 1663.0 |
Final Order | 2018-07-11 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part: a) throughout the site - the employees were exposed to fall hazards and the employer has not initiated an accident prevention program (also known as a safety and health program), on or about 1/31/18. |
Date of last update: 02 Apr 2025