Entity Name: | ASTIZ CONSTRUCTION SERVICES CORP |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
ASTIZ CONSTRUCTION SERVICES CORP is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 12 Jan 2016 (9 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 06 Oct 2017 (8 years ago) |
Document Number: | P16000004354 |
FEI/EIN Number |
81-1138908
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2636 BAHIA RD, WEST PALM BEACH, FL, 33406 |
Mail Address: | 2636 BAHIA RD, WEST PALM BEACH, FL, 33406 |
ZIP code: | 33406 |
County: | Palm Beach |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ASTIZ MATIAS I | President | 2636 BAHIA RD, WEST PALM BEACH, FL, 33406 |
CARDOZO MARIEL E | Vice President | 2636 BAHIA RD, WEST PALM BEACH, FL, 33406 |
ASTIZ MATIAS I | Agent | 2636 BAHIA RD, WEST PALM BEACH, FL, 33406 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REINSTATEMENT | 2017-10-06 | - | - |
REGISTERED AGENT NAME CHANGED | 2017-10-06 | ASTIZ, MATIAS I | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2017-09-22 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-30 |
ANNUAL REPORT | 2023-04-30 |
ANNUAL REPORT | 2022-05-01 |
ANNUAL REPORT | 2021-05-01 |
ANNUAL REPORT | 2020-07-19 |
ANNUAL REPORT | 2019-04-29 |
ANNUAL REPORT | 2018-05-01 |
REINSTATEMENT | 2017-10-06 |
Domestic Profit | 2016-01-12 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342448941 | 0418800 | 2017-06-15 | 6500 NORTH UNIVERSITY DRIVE, TAMARAC, FL, 33321 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2017-08-07 |
Abatement Due Date | 2017-08-17 |
Current Penalty | 2988.0 |
Initial Penalty | 2988.0 |
Final Order | 2017-09-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: On or about 6/15/2017, at the above addressed worksite, employees are performing painting finishing work from an aerial lift at 23 feet above ground level without a lanyard anchored to the basket. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2017-08-07 |
Abatement Due Date | 2017-08-17 |
Current Penalty | 2988.0 |
Initial Penalty | 2988.0 |
Final Order | 2017-09-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. On or about 6/15/2017, at the above addressed worksite, the employer did not train the employees on fall protection and the hazard associated while performing painting finishing work from and aerial lift at 23 feet above ground level. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19030019 D01 |
Issuance Date | 2018-01-11 |
Abatement Due Date | 2018-01-31 |
Current Penalty | 311.0 |
Initial Penalty | 311.0 |
Final Order | 2018-02-08 |
Nr Instances | 2 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: Instances: 1. On or about 6/15/2017, the employer failed to submit abatement documentation for citation 1 item 1 contained in Inspection #1244894, which was issued on 8/07/2017. 2. On or about 6/15/2017, the employer failed to submit abatement documentation for citation 1 item 2 contained in Inspection #1244894, which was issued on 8/07/2017. |