Entity Name: | A.B CONCRETE PUMPING INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
A.B CONCRETE PUMPING INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 28 Dec 2015 (9 years ago) |
Date of dissolution: | 15 Jan 2017 (8 years ago) |
Last Event: | VOLUNTARY DISSOLUTION |
Event Date Filed: | 15 Jan 2017 (8 years ago) |
Document Number: | P15000101612 |
FEI/EIN Number |
47-3875677
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 5781 Lee Blvd, LEHIGH ACRES, FL, 33971, US |
Mail Address: | 5781 Lee Blvd, LEHIGH ACRES, FL, 33971, US |
ZIP code: | 33971 |
County: | Lee |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
Boza Armando | President | 5781 Lee Blvd, LEHIGH ACRES, FL, 33971 |
Boza Armando | Officer | 5781 Lee Blvd, LEHIGH ACRES, FL, 33971 |
BUSINESS FILINGS INCORPORATED | Agent | - |
Event Type | Filed Date | Value | Description |
---|---|---|---|
VOLUNTARY DISSOLUTION | 2017-01-15 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2016-03-08 | 5781 Lee Blvd, ste 208-430, LEHIGH ACRES, FL 33971 | - |
CHANGE OF MAILING ADDRESS | 2016-03-08 | 5781 Lee Blvd, ste 208-430, LEHIGH ACRES, FL 33971 | - |
Name | Date |
---|---|
AMENDED ANNUAL REPORT | 2016-12-18 |
ANNUAL REPORT | 2016-03-08 |
Domestic Profit | 2015-12-28 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341309722 | 0420600 | 2016-03-08 | 28093 WICKLOW COURT, BONITA SPRINGS, FL, 34135 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2016-04-25 |
Abatement Due Date | 2016-05-05 |
Current Penalty | 1400.0 |
Initial Penalty | 2800.0 |
Final Order | 2016-05-09 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) For employees working at 28093 Wicklow Court in Bonita Springs, as observed on or about March 8, 2016. Employees were observed installing roof sheathing on a 6:12 pitch roof. The eave to ground height was approximately 10 feet 7 1/2 inches and the employees had no fall protection system in place. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2016-04-25 |
Current Penalty | 1400.0 |
Initial Penalty | 2800.0 |
Final Order | 2016-05-09 |
Nr Instances | 3 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) For employees working at 28093 Wicklow Court in Bonita Springs, as observed on or about March 8, 2016. Employees were using three ladders to access the upper level landing surface. All three of the ladders were not extended a minimum of 3 feet above the upper landing surface. Two of the ladders extended approximately 1 foot above the landing and the last ladder was flush with the fascia board. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19261053 B16 |
Issuance Date | 2016-04-25 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2016-05-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. a) For employees working at 28093 Wicklow Court in Bonita Springs, as observed on or about March 8, 2016. Employees were observed using a damaged ladder to gain access to the upper landing surface. The fiberglass ladder in use had broken and split rails. |
Date of last update: 01 Mar 2025
Sources: Florida Department of State