Entity Name: | ELMER COOK CONSTRUCTION, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
ELMER COOK CONSTRUCTION, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 21 Dec 2015 (9 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 20 Aug 2018 (7 years ago) |
Document Number: | P15000101434 |
FEI/EIN Number |
20-5194988
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 106 Auburn Road, FORT WALTON BEACH, FL, 32547, US |
Mail Address: | 106 Auburn Road, FORT WALTON BEACH, FL, 32547, US |
ZIP code: | 32547 |
County: | Okaloosa |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
Cook Michele S | Secretary | 2403 PALM HARBOR DRIVE, FORT WALTON BEACH, FL, 32547 |
COOK ELMER LII | Agent | 2403 PALM HARBOR DRIVE, FORT WALTON BEACH, FL, 32547 |
COOK ELMER LII | President | 2403 PALM HARBOR DRIVE, FORT WALTON BEACH, FL, 32547 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2021-03-26 | 106 Auburn Road, FORT WALTON BEACH, FL 32547 | - |
CHANGE OF MAILING ADDRESS | 2021-03-26 | 106 Auburn Road, FORT WALTON BEACH, FL 32547 | - |
REINSTATEMENT | 2018-08-20 | - | - |
REGISTERED AGENT NAME CHANGED | 2018-08-20 | COOK, ELMER L, II | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2017-09-22 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2025-02-11 |
ANNUAL REPORT | 2024-01-24 |
ANNUAL REPORT | 2023-03-06 |
ANNUAL REPORT | 2022-01-24 |
ANNUAL REPORT | 2021-02-04 |
ANNUAL REPORT | 2020-01-21 |
ANNUAL REPORT | 2019-02-11 |
REINSTATEMENT | 2018-08-20 |
ANNUAL REPORT | 2016-04-30 |
Domestic Profit | 2015-12-21 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341328433 | 0419700 | 2016-03-15 | 17292 FRONT BEACH ROAD, PANAMA CITY BEACH, FL, 32413 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1132855 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260502 D17 |
Issuance Date | 2016-04-22 |
Current Penalty | 2100.0 |
Initial Penalty | 2800.0 |
Contest Date | 2016-05-16 |
Final Order | 2017-12-29 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: a. On or about January 8, 2016, on the southeast side of a 2/12 pitch roof of a new commercial building, two employees installing waterproofing material to the roof were wearing personal fall protection systems incorrectly and were not protected from a 30 feet fall hazard by the use of a personal fall protection system. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2016-04-22 |
Current Penalty | 2100.0 |
Initial Penalty | 6300.0 |
Contest Date | 2016-05-16 |
Final Order | 2017-12-29 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. On or about March 15, 2016 on the northeast side of a new commercial construction building, the ladder used to access the top of the structure did not extend 3 feet above the upper landing surface, exposing employees to a 12 foot fall hazard. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7911557205 | 2020-04-28 | 0491 | PPP | 2403 Palm Harbor Drive, FORT WALTON BEACH, FL, 32547-3945 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 02 Apr 2025
Sources: Florida Department of State