Search icon

DIEKON CONSTRUCTION INC. - Florida Company Profile

Company Details

Entity Name: DIEKON CONSTRUCTION INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

DIEKON CONSTRUCTION INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 01 Dec 2015 (9 years ago)
Date of dissolution: 27 Sep 2019 (6 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (6 years ago)
Document Number: P15000096511
FEI/EIN Number 27-1179517

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 2130 OLENTARY STEET, SARASOTA, FL, 34231, US
Mail Address: 2130 OLENTARY STEET, SARASOTA, FL, 34231, US
ZIP code: 34231
County: Sarasota
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
DIEKON ROBERT WJR President 2130 OLENTARY STREET, SARASOTA, FL, 34231
DIEKON ROBERT WJR. Agent 2130 OLENTARY STREET, SARASOTA, FL, 34231

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -
REINSTATEMENT 2018-10-16 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2018-09-28 - -
REINSTATEMENT 2017-02-23 - -
REGISTERED AGENT NAME CHANGED 2017-02-23 DIEKON, ROBERT W, JR. -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2016-09-23 - -

Documents

Name Date
REINSTATEMENT 2018-10-16
REINSTATEMENT 2017-02-23
Domestic Profit 2015-12-01
Off/Dir Resignation 2015-12-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343397469 0420600 2018-08-15 1313 RIVERSIDE DRIVE, PALMETTO, FL, 34221
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-08-15
Emphasis L: FALL
Case Closed 2020-10-02

Related Activity

Type Referral
Activity Nr 1368641
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2018-12-13
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2019-02-12
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) For employees working at the site on or about August 15, 2018. Employees were installing wood framing on the roof trusses without the use of a fall protection system in place. Employees exposed to a fall hazard of approximately
Citation ID 01002
Citaton Type Serious
Standard Cited 19261052 C01 I
Issuance Date 2018-12-13
Current Penalty 2217.0
Initial Penalty 2217.0
Final Order 2019-02-12
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) For employees working at the site on or about August 15, 2018. Employees were working on the second floor installing wood framing. Employees were using a stairwell located in the rear of the home that was not equipped with a handrail. Employees exposed to a fall hazard of up to approximately 10 feet
Citation ID 02001
Citaton Type Other
Standard Cited 19040039 A02
Issuance Date 2018-12-13
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2019-02-12
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours. a) At 1313 Riverside Drive in Palmetto, on August 3, 2018, an employee installing trusses fell approximately 10 feet and was hospitalized. The employer notified OSHA on August 9, 2018.
Citation ID 02002
Citaton Type Other
Standard Cited 19260405 G02 IV
Issuance Date 2018-12-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-02-12
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) For employees working at the site on or about August 15, 2018. Employees were using an extension cord to supply power to electrical tools. The extension cord was missing the strain relief.
Citation ID 02003
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2018-12-13
Abatement Due Date 2018-12-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-02-12
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) For employees working at the site on or about August 15, 2018. Employees were installing wood framing on the roof trusses without the use of a fall protection system in place. Employer did not prepare a written certification record for training provided.

Date of last update: 01 May 2025

Sources: Florida Department of State