Search icon

J.G.R. CONSTRUCTION GROUP INC - Florida Company Profile

Company Details

Entity Name: J.G.R. CONSTRUCTION GROUP INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

J.G.R. CONSTRUCTION GROUP INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 30 Nov 2015 (9 years ago)
Last Event: AMENDMENT
Event Date Filed: 16 Oct 2019 (6 years ago)
Document Number: P15000096481
FEI/EIN Number NOT APPLICABLE

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3519 SILVER MAPLE DR, PLANT CITY, FL, 33566, US
Mail Address: 3519 SILVER MAPLE DR, PLANT CITY, FL, 33566, US
ZIP code: 33566
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MARCOS ESTEBAN President 3519 SILVER MAPLE DR, PLANT CITY, FL, 33566
MARCOS ESTEBAN Director 3519 SILVER MAPLE DR, PLANT CITY, FL, 33566
MARCOS ESTEBAN Agent 3519 SILVER MAPLE DR, PLANT CITY, FL, 33566

Events

Event Type Filed Date Value Description
AMENDMENT 2019-10-16 - -
CHANGE OF PRINCIPAL ADDRESS 2019-10-16 3519 SILVER MAPLE DR, PLANT CITY, FL 33566 -
CHANGE OF MAILING ADDRESS 2019-10-16 3519 SILVER MAPLE DR, PLANT CITY, FL 33566 -
REGISTERED AGENT NAME CHANGED 2019-10-16 MARCOS, ESTEBAN -
AMENDMENT 2015-12-18 - -

Documents

Name Date
ANNUAL REPORT 2024-03-12
ANNUAL REPORT 2023-02-27
ANNUAL REPORT 2022-03-30
ANNUAL REPORT 2021-03-04
ANNUAL REPORT 2020-03-24
Amendment 2019-10-16
ANNUAL REPORT 2019-04-11
ANNUAL REPORT 2018-02-07
ANNUAL REPORT 2017-03-03
ANNUAL REPORT 2016-02-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343656963 0420600 2018-12-11 11622 LAKE LUCAYA DRIVE, RIVERVIEW, FL, 33579
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-12-11
Emphasis L: FALL, P: FALL
Case Closed 2020-04-21

Related Activity

Type Inspection
Activity Nr 1385383
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2019-04-17
Abatement Due Date 2019-05-06
Current Penalty 2652.0
Initial Penalty 5304.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: A) At the 11622 Lake Lucaya Drive where employees using pneumatic air guns and power circular saws while installing plywood sheets on the roof of residential construction were not provided with safety glasses. The employees were exposed to wood and nail ricochets eye hazards as observed on or about 12/11/2018.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2019-04-17
Abatement Due Date 2019-05-06
Current Penalty 1515.5
Initial Penalty 3031.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: A) At the 11622 Lake Lucaya Drive where employees used an extension ladder that did not extend at least 3 feet (.9 m) above the eave of the roof. The employees were exposed to a fall hazard of approximately 9 feet 4 inches as observed on or about 12/11/2018.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2019-04-17
Abatement Due Date 2019-05-06
Current Penalty 5304.0
Initial Penalty 10608.0
Final Order 2019-05-09
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): A) At the 11622 Lake Lucaya Drive where four employees installing plywood sheets on a residential roof were exposed to a fall hazard of 18 feet in that they were not using a fall protection system. As observed on or about 12/11/2018. The J.G.R. Construction Group Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 1196468, citation number 01, item number 01, issued on December 15, 2016 and affirmed as a final order on December 27, 2016, with respect to a workplace located at 628 Chatam Walk Dr., Ruskin, FL 33570.
341964682 0420600 2016-12-12 628 CHATAM WALK DR., RUSKIN, FL, 33570
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-12-12
Emphasis L: FALL, P: FALL
Case Closed 2017-11-08

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2016-12-15
Current Penalty 1870.5
Initial Penalty 3741.0
Final Order 2016-12-28
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest system. a. On or about 12/12/2016 628 Chatham Walk Dr. Ruskin FL , employees were an 8 ft. 10 in fall in that no fall protection was worn while conducting sheeting activates.

Date of last update: 01 Apr 2025

Sources: Florida Department of State