Search icon

JDD CONSTRUCTION INC - Florida Company Profile

Company Details

Entity Name: JDD CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

JDD CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 10 Nov 2015 (9 years ago)
Date of dissolution: 20 Jun 2024 (10 months ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 20 Jun 2024 (10 months ago)
Document Number: P15000092401
FEI/EIN Number 47-5531213

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 172 S West Rainbow Court, Lake City FL, FL, 32024, US
Mail Address: 4056 Dalry Dr, JACKSONVILLE, FL, 32246, US
ZIP code: 32024
County: Columbia
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
TAXSMART ACCOUNTING SERVICES LLC Agent -
DEL CID LOPEZ JOSE A President 4056 DALRY DR, JACKSONVILLE, FL, 32246

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2024-06-20 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2021-09-24 - -
CHANGE OF PRINCIPAL ADDRESS 2020-01-02 172 S West Rainbow Court, Lake City FL, FL 32024 -
CHANGE OF MAILING ADDRESS 2020-01-02 172 S West Rainbow Court, Lake City FL, FL 32024 -
AMENDMENT 2019-10-28 - -

Documents

Name Date
VOLUNTARY DISSOLUTION 2024-06-20
Reg. Agent Resignation 2023-01-09
ANNUAL REPORT 2020-01-02
Amendment 2019-10-28
ANNUAL REPORT 2019-04-10
ANNUAL REPORT 2018-02-09
ANNUAL REPORT 2017-05-01
ANNUAL REPORT 2016-02-25
Domestic Profit 2015-11-10

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342243755 0419700 2017-04-12 2941 MONTILLA DR., JACKSONVILLE, FL, 32224
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2017-04-12
Emphasis L: FALL, P: FALL
Case Closed 2018-05-23

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01 I
Issuance Date 2017-05-22
Current Penalty 978.0
Initial Penalty 1630.0
Final Order 2017-06-13
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: a. On or about April 12, 2017, at the second buck of the scaffold, the employer did not ensure that the platform units were installed so that the space between adjacent units were not more than 1 inch wide, exposing employees stuccoing a wall to an 14 feet, 4 inches fall hazard.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2017-05-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-06-13
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a. On or about April 12, 2017, at the second buck of the scaffold, employees applying stucco to a wall of the building were working from a wood board that was 9.5 inches wide, being exposed to an 16 feet fall hazard.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 B03
Issuance Date 2017-05-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-06-13
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling: a. On or about April 12, 2017, at the scaffold, the front edge of all platforms were 18.5 inches or more from the face of the work and no guardrail system had been erected along the front edge of the platform or fall protection was in used, exposing the employees applying stucco to a wall to a 16 feet fall hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2017-05-22
Current Penalty 978.0
Initial Penalty 1630.0
Final Order 2017-06-13
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross-braces were used as a means of access. a. On or about April 12, 2017, at the scaffold, employees stuccoing a wall were exposed to a fall hazard when ladder was not installed to climb up and down from the scaffold platforms. The employees were using the scaffold frame to climb the scaffold.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2017-05-22
Current Penalty 2281.0
Initial Penalty 3803.0
Final Order 2017-06-13
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about April 12, 2017, at the second buck of the scaffold, employees applying stucco to a wall were not protected from falling 16 feet to the ground below by the use of a fall protection system while working from the wood boards that were place between the window openings and the mid-rail of the scaffold.