Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-07-17
|
Emphasis |
N: SVEP, P: FALL, L: FALL
|
Case Closed |
2020-01-30
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2018-12-18 |
Abatement Due Date |
2019-01-15 |
Current Penalty |
3415.0 |
Initial Penalty |
5691.0 |
Final Order |
2019-01-16 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about July 17, 2018, at Lennar at Park Central, 10651 NW 88th Street, building 7, Apex, Doral, FL 33178, employees who were wearing a PFAS harness, but not connected to an anchor point while working on a roof-top applying stucco/plaster(a walking/working surface) were not protected from falling by the use of guardrail systems, safety net systems or personal fall arrest systems; thus exposing the employees to an approximate 36-foot fall hazards. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260502 D21 |
Issuance Date |
2018-12-18 |
Abatement Due Date |
2019-01-15 |
Current Penalty |
3415.0 |
Initial Penalty |
5691.0 |
Final Order |
2019-01-16 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: On or about July 17, 2018, at Lennar at Park Central, 10651 NW 88th Street, building 7, Apex, Doral, FL 33178, the employer failed to ensure that Personal Fall Arrest Systems which had been impact-loaded, and also had signs of heat and sun/weather related damage and other deterioration were inspected and removed from service; thus exposing the employees to a fall hazard. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260451 B01 |
Issuance Date |
2018-12-18 |
Abatement Due Date |
2019-01-15 |
Current Penalty |
7400.0 |
Initial Penalty |
11383.0 |
Final Order |
2019-01-16 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than 1 inch wide: a. On or about July 17, 2018, at Lennar at Park Central, 10651 NW 88th Street, building 7, Apex, Doral, FL 33178, employees working/apply stucco from a supported scaffold, which was positioned on a rooftop more than ten feet above the lower level/ground and was not fully planked or decked between the front uprights and guardrail supports; thus exposing the employees to an approximate 36-foot fall hazard. b. On or about July 17, 2018, at Lennar at Park Central, 10651 NW 88th Street, building 7, Apex, Doral, FL 33178, employees working/apply stucco from a supported scaffold, which was positioned on a breezeway more than ten feet above the lower level/ground and was not fully planked or decked between the front uprights and guardrail supports; thus exposing the employees to an approximate 24-foot fall hazard. P & W Plastering Corp. was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR. 1926.451(b)(1) or its equivalent standard, which was contained in OSHA inspection number 1257357, citation number 01, Item number 001a, and was affirmed as a final order on 03/27/2018, with respect to a workplace located at 15400 NW 97th Avenue, Hialeah, FL 33018. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2018-12-18 |
Abatement Due Date |
2019-01-15 |
Current Penalty |
7400.0 |
Initial Penalty |
11382.0 |
Final Order |
2019-01-16 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a. On or about July 17, 2018, at Lennar at Park Central, 10651 NW 88th Street, building 7, Apex, Doral, FL 33178, employees working/apply stucco from a supported scaffold, which was positioned on a rooftop more than ten feet above the lower level/ground, were not protected from falling to that lower level by the use of a personal fall arrest system or a guardrail system; thus exposing the employees to an approximate 36-foot fall hazard. b. On or about July 17, 2018, at Lennar at Park Central, 10651 NW 88th Street, building 7, Apex, Doral, FL 33178, employees working/apply stucco from a supported scaffold, which was positioned on a breezeway more than ten feet above the lower level/ground, were not protected from falling to that lower level by the use of a personal fall arrest system or a guardrail system; thus exposing the employees to an approximate 24-foot fall hazard. P & W Plastering Corp. was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR. 1926.451(g)(1) or its equivalent standard, which was contained in OSHA inspection number 1257357, citation number 01, Item number 003a, and was affirmed as a final order on 03/27/2018, with respect to a workplace located at 15400 NW 97th Avenue, Hialeah, FL 33018. NOTE: CERTIFICATION AND DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-08-17
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-03-27
|
Related Activity
Type |
Inspection |
Activity Nr |
1257310 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2017-12-07 |
Current Penalty |
1815.0 |
Initial Penalty |
3622.0 |
Final Order |
2018-02-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) On or about 8/16/2017, at the above addressed worksite, employees were exposed to fall hazards while applying stucco from a two-tier scaffold that was not fully planked. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2017-12-07 |
Current Penalty |
1815.0 |
Initial Penalty |
3622.0 |
Final Order |
2018-02-05 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about 8/16/2017, at the above addressed worksite, employees were exposed to fall hazards while using the crossbraces to climb up the scaffold. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2017-12-07 |
Current Penalty |
1815.0 |
Initial Penalty |
3622.0 |
Final Order |
2018-02-05 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) On or about 8/16/2017, at the above addressed worksite, employees were exposed to fall hazards at the side of the townhouse working from a two-tier scaffold that lack guardrails. b) On or about 8/16/2017, at the above addressed worksite, an employee was exposed to a fall hazard while working from on top of two long planks in front of the townhouse that lack guardrails. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 I |
Issuance Date |
2017-12-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-02-05 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a) On or about 8/16/2017, at the above addressed worksite, employees were exposed to fall hazards at the side of the townhouse working from a two-tier scaffold that lack guardrails along the open side and ends of the platforms. b) On or about 8/16/2017, at the above addressed worksite, an employee was exposed to a fall hazard while working from on top of two long planks in front of the townhouse that lack guardrails along the open side and ends of the platforms. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19260451 H02 II |
Issuance Date |
2017-12-07 |
Current Penalty |
1450.0 |
Initial Penalty |
2897.0 |
Final Order |
2018-02-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: On or about 8/16/2017, at the above addressed worksite, employees were exposed to struck-by hazards while stucco was being applied from a two-tier scaffold that lack toeboards. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2017-12-07 |
Abatement Due Date |
2018-01-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-02-05 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about 8/16/2017, at the above addressed worksite, the employer did not ensure the scaffold and scaffold components were inspected for visible defects by a competent person before each work shift. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2017-12-07 |
Abatement Due Date |
2018-01-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-02-05 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): On or about 8/16/2017, at the above addressed work site, the employer did not develop a written hazard communication program, which employees were exposed to Portland Cement during the mixing and application of the stucco. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19101200 G08 |
Issuance Date |
2017-12-07 |
Abatement Due Date |
2018-01-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-02-05 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: On or about 8/16/2017, at the above addressed work site, the employer did not have the safety data sheet readily available at the work site for the stucco cement the employees were applying to the structure. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
|
|