Entity Name: | REYES CONSTRUCTION INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
REYES CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 09 Oct 2015 (10 years ago) |
Last Event: | NAME CHANGE AMENDMENT |
Event Date Filed: | 04 Nov 2019 (5 years ago) |
Document Number: | P15000083542 |
FEI/EIN Number |
30-0889565
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1971, WEST LUMSDEN RD, BRANDON, FL, 33511, US |
Mail Address: | 1971 W Lumsden Rd, Brandon, FL, 33511, US |
ZIP code: | 33511 |
County: | Hillsborough |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
reyes christina | President | 1971, BRANDON, FL, 33511 |
Reyes Christina | Agent | 1971, BRANDON, FL, 33511 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
CHANGE OF PRINCIPAL ADDRESS | 2023-01-03 | 1971, WEST LUMSDEN RD, 165, BRANDON, FL 33511 | - |
REGISTERED AGENT NAME CHANGED | 2023-01-03 | Reyes, Christina | - |
REGISTERED AGENT ADDRESS CHANGED | 2023-01-03 | 1971, WEST LUMSDEN RD, 165, BRANDON, FL 33511 | - |
CHANGE OF MAILING ADDRESS | 2022-05-01 | 1971, WEST LUMSDEN RD, 165, BRANDON, FL 33511 | - |
NAME CHANGE AMENDMENT | 2019-11-04 | REYES CONSTRUCTION INC | - |
Document Number | Status | Case Number | Name of Court | Date of Entry | Expiration Date | Amount Due | Plaintiff |
---|---|---|---|---|---|---|---|
J23000495747 | ACTIVE | 1000000966676 | HILLSBOROU | 2023-10-06 | 2033-10-18 | $ 982.50 | STATE OF FLORIDA, DEPARTMENT OF REVENUE, TAMPA SERVICE CENTER, 5483 W WATERS AVE STE 1210, TAMPA FL336341236 |
J22000341703 | TERMINATED | 1000000928433 | HILLSBOROU | 2022-07-12 | 2032-07-13 | $ 385.66 | STATE OF FLORIDA, DEPARTMENT OF REVENUE, TAMPA SERVICE CENTER, 5483 W WATERS AVE STE 1210, TAMPA FL336341236 |
J21000654115 | TERMINATED | 1000000910123 | HILLSBOROU | 2021-12-14 | 2031-12-22 | $ 1,047.37 | STATE OF FLORIDA, DEPARTMENT OF REVENUE, TAMPA SERVICE CENTER, 5483 W WATERS AVE STE 1210, TAMPA FL336341236 |
Name | Date |
---|---|
ANNUAL REPORT | 2025-01-21 |
AMENDED ANNUAL REPORT | 2024-07-30 |
AMENDED ANNUAL REPORT | 2024-06-04 |
ANNUAL REPORT | 2024-03-04 |
ANNUAL REPORT | 2023-01-03 |
ANNUAL REPORT | 2022-05-01 |
ANNUAL REPORT | 2021-03-26 |
ANNUAL REPORT | 2020-05-05 |
Name Change | 2019-11-04 |
ANNUAL REPORT | 2019-04-29 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339370835 | 0420600 | 2013-08-30 | 181 ALEXANDER WOODS DR., PLANT CITY, FL, 33566 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2013-12-03 |
Current Penalty | 650.5 |
Initial Penalty | 1301.0 |
Final Order | 2013-12-20 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) At the site - the employees were exposed to a 14 foot fall while worikng from a scaffold that was not protected by endrails on the second floor. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2013-12-03 |
Current Penalty | 612.0 |
Initial Penalty | 1224.0 |
Final Order | 2013-12-20 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) At the site - the employees were exposed to an 8 foot fall while working from the second floor of the building. The open sides were not protected by temporary rails. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260451 C02 II |
Issuance Date | 2013-12-03 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-12-20 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: (a) At the site - concrete blocks were stacked on top of two planks to support the scaffold system. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19261053 B01 |
Issuance Date | 2013-12-03 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-12-20 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) At the site - the employees were using a portable ladder that was not extended above the landing when accessing the 2nd floor. |
Date of last update: 01 Apr 2025