Search icon

VALADEZ CORP - Florida Company Profile

Company Details

Entity Name: VALADEZ CORP
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

VALADEZ CORP is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 20 Aug 2015 (10 years ago)
Date of dissolution: 22 Dec 2016 (8 years ago)
Last Event: VOLUNTARY DISSOLUTION
Event Date Filed: 22 Dec 2016 (8 years ago)
Document Number: P15000070175
FEI/EIN Number 47-4905115

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 628 NW 13 STREET, APT 13, BOCA RATON, FL, 33486, US
Mail Address: 628 NW 13 STREET, APT 13, BOCA RATON, FL, 33486, US
ZIP code: 33486
County: Palm Beach
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
VALADEZ JORGE A President 628 NW 13 STREET, BOCA RATON, FL, 33486
VALADEZ JORGE A Agent 628 NW 13 STREET, BOCA RATON, FL, 33486

Events

Event Type Filed Date Value Description
VOLUNTARY DISSOLUTION 2016-12-22 - -
CHANGE OF PRINCIPAL ADDRESS 2016-08-08 628 NW 13 STREET, APT 13, BOCA RATON, FL 33486 -
CHANGE OF MAILING ADDRESS 2016-08-08 628 NW 13 STREET, APT 13, BOCA RATON, FL 33486 -
REGISTERED AGENT ADDRESS CHANGED 2016-08-08 628 NW 13 STREET, APT 13, BOCA RATON, FL 33486 -

Documents

Name Date
ANNUAL REPORT 2016-08-08
Domestic Profit 2015-08-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341843217 0419700 2016-10-17 1515 PRUDENTIAL DRIVE, JACKSONVILLE, FL, 32207
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-10-17
Emphasis L: FALL, P: FALL
Case Closed 2020-08-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2016-10-26
Abatement Due Date 2016-11-01
Current Penalty 1090.0
Initial Penalty 1817.0
Final Order 2016-11-17
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On October 17, 2016, on the ground and lower roofs, employees handling plywood were not wearing a hard hat, exposing themselves to an overhead hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2016-10-26
Abatement Due Date 2016-11-01
Current Penalty 1090.0
Initial Penalty 1817.0
Final Order 2016-11-17
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On October 17, 2016, on the roof, employees using nail guns and a power saw to cut plywood were not wearing safety glasses, exposing themselves to an eye hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2016-10-26
Abatement Due Date 2016-11-01
Current Penalty 2245.0
Initial Penalty 3741.0
Final Order 2016-11-17
Nr Instances 3
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a. On October 17, 2016, on the top roof, employees nailing plywood sheathing were not protected from a 13 feet fall hazard by the use of a fall protection system. b. On October 17, 2016, on the middle roof, employees handling plywood were not protected from an 10 feet fall hazard by the use of a fall protection system. c. On October 17, 2016, on the lower roof, employees handling plywood were not protected from an 18 feet fall hazard by the use of a fall protection system.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2016-10-26
Abatement Due Date 2016-11-01
Current Penalty 1090.0
Initial Penalty 1817.0
Final Order 2016-11-17
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On October 17, 2016, the ladder used to access the 3rd level did not extend 3 feet above the landing, exposing employees to an 8 feet fall hazard. b. On October 17, 2016, the ladder used to access the 4th level did not extend 3 feet above the landing, exposing employees to an 8 feet fall hazard. c. On October 17, 2016, the ladder used to access the top level roof did not extend 3 feet above the landing, exposing employees to a 13 feet fall hazard.