Entity Name: | EZ CONCEPTS FLOORING, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Profit Corporation
EZ CONCEPTS FLOORING, INC. is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 07 Aug 2015 (10 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 13 Mar 2017 (8 years ago) |
Document Number: | P15000066918 |
FEI/EIN Number |
47-4758201
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 4997 NW 95TH AVENUE, SUNRISE, FL 33351 |
Mail Address: | 4997 NW 95TH AVENUE, SUNRISE, FL 33351 |
ZIP code: | 33351 |
County: | Broward |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
ZAGA, ERIC F | Agent | 4997 NW 95TH AVENUE, SUNRISE, FL 33351 |
ZAGA, ERIC F | President | 4997 NW 95TH AVENUE, SUNRISE, FL 33351 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REINSTATEMENT | 2017-03-13 | - | - |
REGISTERED AGENT NAME CHANGED | 2017-03-13 | ZAGA, ERIC F | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2016-09-23 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-04 |
ANNUAL REPORT | 2023-04-26 |
ANNUAL REPORT | 2022-05-03 |
ANNUAL REPORT | 2021-02-01 |
ANNUAL REPORT | 2020-06-21 |
ANNUAL REPORT | 2019-06-18 |
ANNUAL REPORT | 2018-09-16 |
REINSTATEMENT | 2017-03-13 |
Domestic Profit | 2015-08-07 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342465333 | 0418800 | 2017-07-13 | 2710 NE 20TH COURT, FORT LAUDERDALE, FL, 33304 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2017-07-21 |
Abatement Due Date | 2017-08-02 |
Current Penalty | 815.0 |
Initial Penalty | 1630.0 |
Final Order | 2017-08-29 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) On or about July 13, 2017, at the above addressed jobsite, an employee was working on a metal platform from a tubular welded scaffold up to approximately 8 feet high without the platform being fully planked, exposing the employee to a fall hazard. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2017-07-21 |
Abatement Due Date | 2017-08-02 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-08-29 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: On or about July 13, 2017, at the above addressed jobsite, an employee without training to recognize the hazards associated with the type of scaffolding being used was working from a tubular welded scaffold while exposed to a fall hazard of up to approximately 8 feet high. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2017-07-21 |
Abatement Due Date | 2017-07-31 |
Current Penalty | 815.0 |
Initial Penalty | 1630.0 |
Final Order | 2017-08-29 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: On or about July 13, 2017, at the above addressed jobsite, an employee was working accessing a scaffold up to approximately 8 feet high without a ladder, exposing the employee to a fall hazard. |
Date of last update: 19 Feb 2025