Search icon

GALLART CONSTRUCTION SERVICES, INC - Florida Company Profile

Company Details

Entity Name: GALLART CONSTRUCTION SERVICES, INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

GALLART CONSTRUCTION SERVICES, INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 12 Jun 2015 (10 years ago)
Date of dissolution: 22 Sep 2017 (8 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 22 Sep 2017 (8 years ago)
Document Number: P15000051983
FEI/EIN Number APPLIED FOR

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 814 58TH AVE DR EAST, BRADENTON, FL, 34203
Mail Address: P.O. BOX 3846, SARASOTA, FL, 34230, US
ZIP code: 34203
County: Manatee
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
TU LATINO TAX SERVICES, INC Agent -
Palacios Roberto A President 814 58TH AVE DR EAST, BRADENTON, FL, 34203

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2017-09-22 - -
AMENDMENT 2015-09-21 - -
CHANGE OF MAILING ADDRESS 2015-07-22 814 58TH AVE DR EAST, BRADENTON, FL 34203 -

Documents

Name Date
ANNUAL REPORT 2016-05-05
Amendment 2015-09-21
Domestic Profit 2015-06-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340932490 0420600 2015-09-21 7421 SEACROFT COVE, LAKEWOOD RANCH, FL, 34202
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-09-21
Emphasis L: FALL, P: FALL
Case Closed 2020-10-02

Related Activity

Type Inspection
Activity Nr 1093252
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-11-10
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On the 6/12 pitched roof, fall protection was not provided exposing employees to an 11-18 foot fall hazard, on or about 9/21/15.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2015-11-10
Abatement Due Date 2015-11-23
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. At the jobsite, employees working on a 6/12 pitched roof were not provided fall protection training, exposing employees to an 11-18 foot fall hazard, on or about 9/21/15.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2015-11-10
Current Penalty 1360.0
Initial Penalty 1360.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. At the jobsite, the portable extension ladder used to gain access to the roof extended approximately 12 inches past the landing surface, exposing employees to an 11 foot fall hazard, on or about 9/21/15.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B08
Issuance Date 2015-11-10
Current Penalty 1360.0
Initial Penalty 1360.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: a. At the jobsite, the portable extension used to access the roof was not secured from displacement, exposing employees to an 11 foot fall hazard, on or about 9/21/15.
340932235 0420600 2015-09-17 8711 TURNSTONE HAVEN PL., TAMPA, FL, 33602
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-09-17
Emphasis L: FALL, P: FALL
Case Closed 2020-02-07

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B15
Issuance Date 2015-10-23
Current Penalty 1360.0
Initial Penalty 1360.0
Final Order 2016-01-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(15): Each employee on a walking/working surface 6 feet (1.8 meters) or more above lower levels was not protected from falling by a guardrail system, safety net system, or personal fall arrest system: (a) At the site - fall protection was not provided when walking the concrete wall exposing the employee to a 10 foot fall hazard, on or about 9/17/2015.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2015-10-23
Current Penalty 1020.0
Initial Penalty 1020.0
Final Order 2016-01-05
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: (a) At the site - the top step of the metal portable ladder was used to reach the assigned work area exposing an employee to a 6 foot fall, on or about 9/17/2015.

Date of last update: 01 Apr 2025

Sources: Florida Department of State