341210698
|
0420600
|
2016-01-28
|
10980 OAK ST., SAINT PETERSBURG, FL, 33710
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-01-28
|
Emphasis |
L: FALL
|
Case Closed |
2017-06-02
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B11 |
Issuance Date |
2016-05-05 |
Current Penalty |
15400.0 |
Initial Penalty |
15400.0 |
Final Order |
2016-06-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a. At the job site, employees installing roof trusses were exposed to 10 foot fall hazard, in that, fall protection was not used, on or about 01/28/2016. THE COPA CONSTRUCTION INC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(B)(13), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1117673, CITATION NUMBER 01, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON 04/07/2016, WITH RESPECT TO A WORKPLACE LOCATED AT 208 WEST AMELIA AVENUE, TAMPA, FL 33602. THE COPA CONSTRUCTION INC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(B)(13), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1087548, CITATION NUMBER 01, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON 10/27/2015, WITH RESPECT TO A WORKPLACE LOCATED AT 18958 LUTTERWORTH COURT, LAND O LAKES, FL 34638. THE COPA CONSTRUCTION INC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(B)(13), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1095387, CITATION NUMBER 01, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON 2/1/2016, WITH RESPECT TO A WORKPLACE LOCATED AT 32437 NATURAL BRIDGE RD., WESLEY CHAPEL FL 33534. |
|
|
341176733
|
0420600
|
2016-01-14
|
208 W AMELIA AVE, TAMPA, FL, 33602
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-01-14
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2016-05-16
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-03-29 |
Current Penalty |
2800.0 |
Initial Penalty |
5600.0 |
Final Order |
2016-04-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On the 6/12 pitch roof, employees who were installing decking were exposed to a 12 foot fall from the 6/12 pitch roof, in that, the employer failed to ensure the use of fall protection on or about 6/12/2015. The Copa Construction Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1087548, citation number 01, item number 001 and was affirmed as a final order on 10/27/2015, with respect to a workplace located at 18958 Lutterworth Court, Land O Lakes, FL 34638. The Copa Construction Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1095387, citation number 01, item number 001 and was affirmed as a final order on 2/1/2016, with respect to a workplace located at 32437 Natural Bridge Rd., Wesley Chapel FL 33534. |
|
|
340953876
|
0420600
|
2015-09-30
|
32437 NATURAL BRIDGE RD., WESLEY CHAPEL, FL, 33543
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-09-30
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-05-16
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2015-12-28 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-02-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. In the roof trusses, fall protection was not provided to employees receiving wood truss frames from a mobile crane, exposing the employees to a 20 foot fall hazard, on or about 9/30/2015. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2015-12-28 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-02-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. At the jobsite, the portable extension ladder used to access the second floor extended less than one rung past the landing, exposing employees to an 11 foot fall hazard, on or about 9/30/2015. |
|
|
340875483
|
0420600
|
2015-08-26
|
18958 LUTTERWORTH COURT, LAND O LAKES, FL, 34638
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-08-26
|
Emphasis |
P: FALL, L: FALL, L: EISAOF
|
Case Closed |
2017-05-16
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2015-09-29 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-10-27 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On the 5/12 pitched roof, fall protection was not provided, exposing employees to a 8-20 foot fall hazard, on or about 8/26/2015. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 II |
Issuance Date |
2015-09-29 |
Current Penalty |
2400.0 |
Initial Penalty |
2400.0 |
Final Order |
2015-10-27 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stair-rail system along each unprotected side or edge: a. Along the inside staircase, the stair-rail system was missing, exposing employees to a 10 foot fall hazard, on or about 8/26/2015. |
|
|