Search icon

KENNETH COPT PLASTERING CORP - Florida Company Profile

Company Details

Entity Name: KENNETH COPT PLASTERING CORP
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

KENNETH COPT PLASTERING CORP is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 12 May 2015 (10 years ago)
Date of dissolution: 22 Sep 2023 (a year ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 22 Sep 2023 (a year ago)
Document Number: P15000042761
FEI/EIN Number 465752806

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 13620 SW 102 AVE, MIAMI, FL, 33176, US
Mail Address: 13620 SW 102 AVE, MIAMI, FL, 33176, US
ZIP code: 33176
County: Miami-Dade
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ZELAYA OMAR L President 13620 SW 102 AVE, MIAMI, FL, 33176
MARTINEZ ANTONIO ADOLFO Secretary 13620 SW 102 AVE, MIAMI, FL, 33176
ZELAYA OMAR L Agent 13620 SW 102 AVE, MIAMI, FL, 33176

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2023-09-22 - -
CHANGE OF PRINCIPAL ADDRESS 2022-04-27 13620 SW 102 AVE, MIAMI, FL 33176 -
CHANGE OF MAILING ADDRESS 2022-04-27 13620 SW 102 AVE, MIAMI, FL 33176 -
REGISTERED AGENT ADDRESS CHANGED 2022-04-27 13620 SW 102 AVE, MIAMI, FL 33176 -
AMENDMENT 2017-05-23 - -
AMENDMENT 2015-05-19 - -

Documents

Name Date
ANNUAL REPORT 2022-04-27
ANNUAL REPORT 2021-04-29
ANNUAL REPORT 2020-06-03
ANNUAL REPORT 2019-01-11
ANNUAL REPORT 2018-02-22
Amendment 2017-05-23
ANNUAL REPORT 2017-05-11
ANNUAL REPORT 2016-04-29
Amendment 2015-05-19
Domestic Profit 2015-05-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344793815 0418800 2020-06-17 9500 SW 61TH CT, PINECREST, FL, 33156
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2020-06-17
Emphasis L: FALL, P: FALL
Case Closed 2023-04-13

Related Activity

Type Inspection
Activity Nr 1479396
Safety Yes
Type Complaint
Activity Nr 1606263
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2020-06-23
Abatement Due Date 2020-07-01
Current Penalty 1156.5
Initial Penalty 2313.0
Final Order 2020-07-23
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and maintain at each workplace, a written hazard communication program which at least described how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also included the requirements specified in (e)(1)(i) and (e)(1)(ii): (Construction Reference 1926.59) On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, the employer did not develop and implement a written hazard communication program for employees who work with hazardous chemicals including, but not limited to, Titan America Stucco and Roof Tile Cement containing Portland cement a corrosive (with a pH of 11.5).
Citation ID 01001B
Citaton Type Serious
Standard Cited 19101200 G01
Issuance Date 2020-06-23
Abatement Due Date 2020-07-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-07-23
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: (Construction Reference 1926.59) On or about 6/11/2010, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, the employer did not have available safety data sheets (SDS) for employees exposed to a hazardous chemicals including, but not limited to, Titan America Stucco and Roof Tile Cement containing Portland cement a corrosive (with a pH of 11.5).
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B01 I
Issuance Date 2020-06-23
Current Penalty 2428.8
Initial Penalty 4048.0
Final Order 2020-07-23
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: On or about 6/11/2010, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, employees were exposed to the hazard of falling up to 18'-0" to ground level while working from tubular welded frame scaffolds that were not fully planked.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 B05 I
Issuance Date 2020-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-07-23
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length, extended over its support more than 12 inches: On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, an employee worked from a scaffold platform which extended over 56" over its support, which exposed employee to a fall hazard of 5' and 18' approximately to residence balcony floor and ground level, respectively.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 B07
Issuance Date 2020-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-07-23
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(7): On scaffolds where platforms are overlapped to create a long platform, the overlap did not occur only over supports: On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, two employees worked from scaffold platforms that overlapped without being supported, which exposed employees to a fall hazard of 5' and 18' approximately to residence balcony floor and ground level, respectively.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2020-06-23
Current Penalty 2428.8
Initial Penalty 4048.0
Final Order 2020-07-23
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, employees were exposed to the hazard of falling up to 18'-0" to ground level while working from tubular welded frame scaffolds whose frames were placed over concrete but lacked base plates.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2020-06-23
Current Penalty 2428.8
Initial Penalty 4048.0
Final Order 2020-07-23
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, employees were exposed to the hazard of falling up to 18'-0" to ground level while working from tubular welded frame scaffolds that lacked a safe means of access.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2020-06-23
Current Penalty 2428.8
Initial Penalty 4048.0
Final Order 2020-07-23
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, employees were exposed to a fall hazard while plastering from tubular welded frame scaffolds that were erected without supervision, as evidenced by, among other conditions; scaffold was not fully planked; scaffold platforms were not adequately supported; scaffolds lacked of cross braces, etc.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2020-06-23
Current Penalty 2833.6
Initial Penalty 4048.0
Final Order 2020-07-23
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, two employees were exposed to the hazard of falling 18'-0" to ground level while working from scaffolds without being protected from falling. b. On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, an employee was exposed to the hazard of falling 12'-0" to ground level while working from scaffolds without being protected from falling.
Citation ID 01007
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2020-06-23
Current Penalty 2428.8
Initial Penalty 4048.0
Final Order 2020-07-23
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: On or about 6/11/2020, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, employees were exposed to the hazard of falling up to 18'-0" to ground level while working from a tubular welded frame scaffolds that lacked cross braces in the portion facing wall.
Citation ID 02001
Citaton Type Other
Standard Cited 19040039 A02
Issuance Date 2020-06-23
Abatement Due Date 2020-06-29
Current Penalty 1446.0
Initial Penalty 2892.0
Final Order 2020-07-23
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye: On or about 6/11/2010, at jobsite located at 9500 SW 61st Ct, Pinecrest, FL 33156, the employer did not report a work-related incident that took place on 6/11/2020, which resulted in an employee hospitalization after suffering multiple fractures.