341931509
|
0420600
|
2016-11-16
|
10616 WHISPERING HAMMOCK DRIVE, RIVERVIEW, FL, 33578
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-11-16
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2019-07-08
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2017-03-01 |
Current Penalty |
3386.0 |
Initial Penalty |
3386.0 |
Final Order |
2017-03-28 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a. For employees using a 10 feet high stepladder to access from the first to the second level with a landing surface of 10 feet above inside a new construction residence to conduct carpentry work. On or about 11/16/2016. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2017-03-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-03-28 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a. For employees using a 10 feet high stepladder to access from the first to the second level with a landing surface of 10 feet above inside a new construction residence to conduct carpentry work. On or about 11/16/2016. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B01 |
Issuance Date |
2017-03-01 |
Current Penalty |
11154.0 |
Initial Penalty |
11154.0 |
Final Order |
2017-03-28 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. Employees were exposed to a fall hazard of 10 feet from a stairwell opening while conducting carpentry work on the second level of a new construction residence. On or about 11/16/2016. THE UNITED FL CONSTRUCTION INC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(B)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1147466, CITATION NUMBER 01, ITEM NUMBER 002 AND WAS AFFIRMED AS A FINAL ORDER ON 07/27/2016, WITH RESPECT TO A WORKPLACE LOCATED AT 15133 SR 54, ODESSA, FL 33556. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2017-03-01 |
Abatement Due Date |
2017-03-13 |
Current Penalty |
27885.0 |
Initial Penalty |
27885.0 |
Final Order |
2017-03-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. Employees were exposed to a fall hazard of 18 feet and 10 inches while sheathing roof of a new construction residence, in that, fall protection was not used. On or about 11/16/2016. THE UNITED FL CONSTRUCTION INC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(B)(13), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1126089, CITATION NUMBER 01, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON 04/15/2016, WITH RESPECT TO A WORKPLACE LOCATED AT 1200 MUZANO STREET, KISSIMMEE, FL 34741. THE UNITED FL CONSTRUCTION INC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(B)(13), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1155701, CITATION NUMBER 01, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON 10/12/2016, WITH RESPECT TO A WORKPLACE LOCATED AT 2140 and 2195 CABOOSE LANE, ODESSA, FL 33556. |
|
|
341836377
|
0420600
|
2016-10-13
|
5818 RONALD REGAN PKWY, DAVENPORT, FL, 33836
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-10-13
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-10-02
|
Related Activity
Type |
Inspection |
Activity Nr |
1183697 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-11-03 |
Current Penalty |
5487.0 |
Initial Penalty |
5487.0 |
Final Order |
2016-12-05 |
Nr Instances |
3 |
Nr Exposed |
22 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. Building 11, employees were exposed to a 10 foot fall hazard, in that, fall protection was not used during framing work at the second floor balconies of the building, on or about 10/13/2016. b. Building 8, employees were exposed to a 20 foot fall hazard, in that, fall protection was not used during roof joist framing work, on or about 10/13/2016. c. Building 8 and 11, employees were exposed to a 10 foot fall hazard, in that, fall protection was not used during framing work at the second floor windows where standard railings were not installed on all window openings, on or about 10/13/2016. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260405 A02 II I |
Issuance Date |
2016-11-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-12-05 |
Nr Instances |
1 |
Nr Exposed |
22 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: a. At the yard area, employees were exposed to an electrical hazard, in that, extension cords were run across the road and were subject to getting run over by vehicular traffic without being protected from damage, on or about 10/13/2016. |
|
|
341557015
|
0420600
|
2016-06-15
|
2140 AND 2195 CABOOSE LN., ODESSA, FL, 33556
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-06-15
|
Emphasis |
L: FALL
|
Case Closed |
2020-10-02
|
Related Activity
Type |
Complaint |
Activity Nr |
1100393 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-09-13 |
Abatement Due Date |
2016-09-23 |
Current Penalty |
10974.0 |
Initial Penalty |
10974.0 |
Final Order |
2016-10-12 |
Nr Instances |
2 |
Nr Exposed |
9 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. At building 5, employees installing floor joists were exposed to a 21 feet 3 inches and a 10 feet 8 inch fall hazards, in that, fall protection was not used. On or about 06/13/2016. b. At building 7, an employee laying out the building was exposed to a 9 feet 1 inch fall hazard, in that, fall protection was not used. On or about 06/13/2016. THE UNITED FL CONSTRUCTION INC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1926.501(B)(13), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1126089, CITATION NUMBER 01, ITEM NUMBER 001 AND WAS AFFIRMED AS A FINAL ORDER ON 07/29/2016, WITH RESPECT TO A WORKPLACE LOCATED AT 1200 MUZANO STREET, KISSIMMEE, FL 34741. |
|
|
341474666
|
0420600
|
2016-05-11
|
15133 SR 54, ODESSA, FL, 33556
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-05-11
|
Emphasis |
L: FALL, P: FALL, N: CTARGET
|
Case Closed |
2016-08-18
|
Related Activity
Type |
Inspection |
Activity Nr |
1147431 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1147449 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1151544 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260020 B02 |
Issuance Date |
2016-06-14 |
Current Penalty |
1960.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-07-27 |
Nr Instances |
1 |
Nr Exposed |
19 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s) a. At the site, buildings 9 and 10, employees were exposed to a fall hazard, in that, frequent and regular inspections were not conducted to assure that employees were protected from fall hazards during framing work in multistory buildings, on or about 05/11/2016. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2016-06-14 |
Current Penalty |
1960.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-07-27 |
Nr Instances |
2 |
Nr Exposed |
19 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a. Building 9, employees were exposed to a 31 feet fall hazard, in that, fall protection was not used during floor joist and exterior wall framing work, at the second and third floor of the building, on or about 05/11/2016. b. Building 10, employees were exposed to a 22 feet fall hazard, in that, fall protection was not used during roof truss and sheathing framing work, at the roof of the two story building, on or about 05/11/2016. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2016-06-14 |
Current Penalty |
1960.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-07-27 |
Nr Instances |
1 |
Nr Exposed |
19 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. Employees exposed to a fall hazard were not provided training and education relating to fall protection, hazard recognition, procedures to be followed to minimize these hazards and the proper use and limitations of fall protection equipment and fall protection systems, on or about 05/11/2016. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260405 A02 II I |
Issuance Date |
2016-06-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-27 |
Nr Instances |
3 |
Nr Exposed |
19 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: a. At the site near building 10, employees were exposed to an electrical hazard, in that, a temporary multi-outlet power supply box was used by having the extension cord run across the road from a generator to a supply box and subject to getting run over by vehicular traffic and forklift traffic, on or about 05/11/2016. b. At the site, employees were exposed to an electrical hazard, in that, power was run from a generator using extension cords placed across the road to building 9 and was subject to getting run over by vehicular traffic and forklift traffic, on or about 05/11/2016. c. At the entrance of the site, employees were exposed to an electrical hazard, in that, power was run from the temporary supply to building 9 using extension cords placed across the road and was subject to getting run over by vehicular traffic and forklift traffic, on or about 05/11/2016. |
|
|
341260891
|
0420600
|
2016-02-18
|
1200 MUZANO STREET, KISSIMMEE, FL, 34741
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-02-18
|
Emphasis |
L: FALL, N: CTARGET, P: CTARGET
|
Case Closed |
2016-07-07
|
Related Activity
Type |
Inspection |
Activity Nr |
1126077 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-03-17 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-04-15 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. At the jobsite, fall protection was not provided to employees doing framing work and installing plywood sheeting on a multi-level residential building, exposing employees to a 22 foot fall hazard, on or about 2/18/16. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261051 A |
Issuance Date |
2016-03-17 |
Current Penalty |
1224.0 |
Initial Penalty |
2040.0 |
Final Order |
2016-04-15 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a. At the jobsite, access to the 3rd level was gained by climbing the wood framing, exposing employees to a 10 foot fall hazard, on or about 2/18/16. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261060 A01 III |
Issuance Date |
2016-03-17 |
Abatement Due Date |
2016-03-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-04-15 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways: a. At the jobsite, employees using an extension ladder to access the 3rd floor were not trained by a competent person, exposing the employees to a 10 foot fall hazard, on or about 2/18/16. |
|
|