Search icon

SHADE CHASERS VINYL INC. - Florida Company Profile

Company Details

Entity Name: SHADE CHASERS VINYL INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

SHADE CHASERS VINYL INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 03 Mar 2015 (10 years ago)
Date of dissolution: 22 Sep 2017 (8 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 22 Sep 2017 (8 years ago)
Document Number: P15000020830
FEI/EIN Number 47-3467463

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 3158 COLLEGE STREET, JACKSONVILLE, FL, 32205
Mail Address: 3158 COLLEGE STREET, JACKSONVILLE, FL, 32205
ZIP code: 32205
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
ROBERTSON CARL President 3158 COLLEGE RD, JACKSONVILLE, FL, 32205
GOOGE DANIEL Vice President 2018 ROTHBURY DR, JACKSONVILLE, FL, 32210
ROBERTSON CARL Agent 3158 COLLEGE STREET, JACKSONVILLE, FL, 32205
RHODES KYLE R Secretary 7246 ELVIA DR, JACKSONVILLE, FL, 32211

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2017-09-22 - -

Documents

Name Date
ANNUAL REPORT 2016-02-10
Domestic Profit 2015-03-03

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342193331 0419700 2017-03-22 4081 COASTAL AVE, JACKSONVILLE, FL, 32250
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2017-03-22
Emphasis L: FALL, P: FALL
Case Closed 2020-10-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2017-03-30
Current Penalty 1108.2
Initial Penalty 1847.0
Final Order 2017-04-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets: a. On March 22, 2017, employees were working on the ground and lower level roof without a hard hat below employees installing soffit above, exposing themselves to an overhead hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2017-03-30
Current Penalty 1108.2
Initial Penalty 1847.0
Final Order 2017-04-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a. On March 22, 2017, employees using pneumatic nail guns to install soffit were not wearing safety glasses, exposing themselves to the hazard of being struck in the eye by nails and debris.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-03-30
Current Penalty 2281.8
Initial Penalty 3803.0
Final Order 2017-04-24
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. On March 22, 2017, on the lower level roof, employees installing the soffit were not protected from a 10 feet fall hazard by the use of a fall protection system. b. On March 22, 2017, on the upper level roof, employees installing the soffit were not protected from a 19 feet fall hazard by the use of a fall protection system.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2017-03-30
Current Penalty 1385.4
Initial Penalty 2309.0
Final Order 2017-04-24
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: a. On March 22, 2017, the ladder used to access the upper level roof did not extend 3 feet above the eave, exposing employees to a 19 feet fall hazard.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2017-03-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-04-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a. On March 22, 2017, the ladder used to access the upper level roof was positioned at a one to one ratio exposing employees to 19 feet fall hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2017-03-30
Abatement Due Date 2017-05-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-04-24
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): A safety and health program was not initiated and maintained to provide compliance with the general safety and health provisions of the standard: a. On March 22, 2017, the employer did not have a safety and health program for employees working from ladders and scaffolds.
Citation ID 02002
Citaton Type Other
Standard Cited 19260050 D01
Issuance Date 2017-03-30
Abatement Due Date 2017-05-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-04-24
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.50(d)(1): First-aid supplies were not easily accessible when required: a. On March 22, 2017, employees installing soffit from ladders and scaffolds did not have a first aid kit on the job site.

Date of last update: 01 Apr 2025

Sources: Florida Department of State