341595254
|
0418800
|
2016-06-29
|
1570 N FEDERAL HIGHWAY, FORT LAUDERDALE, FL, 33304
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-06-29
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-04-13
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2016-07-22 |
Current Penalty |
3500.0 |
Initial Penalty |
3500.0 |
Final Order |
2016-08-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about June 29. 2016, at the above addressed jobsite, an employee was applying stucco from a scaffold platform that was not fully planked, exposing him to a fall hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2016-07-22 |
Current Penalty |
3500.0 |
Initial Penalty |
3500.0 |
Final Order |
2016-08-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about June 29, 2016, at the above addressed jobsite, an employee did not have safe access from a scaffold platform, exposing him to a fall hazard. |
|
|
341376358
|
0418800
|
2016-03-30
|
54150 DAVIE ROAD EXTENSION, HOLLYWOOD, FL, 33024
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-03-30
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-10-19
|
Related Activity
Type |
Inspection |
Activity Nr |
1137672 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1137623 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2016-09-28 |
Abatement Due Date |
2016-10-11 |
Current Penalty |
3563.0 |
Initial Penalty |
3563.0 |
Final Order |
2016-11-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. On or about March 30, 2016, at the above addressed job site, employees were exposed to struck-by eye injuries while installing metal lath with pneumatic staple guns and using adhesive without a means of eye protection. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2016-09-28 |
Abatement Due Date |
2016-10-11 |
Current Penalty |
2850.0 |
Initial Penalty |
2850.0 |
Final Order |
2016-11-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about March 30, 2016, at the above addressed job site, employees were exposed to a fall hazard of approximately 9 feet while using an extension ladder that was not extended 3 feet above the upper roof landing and lacked a grasping device. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 B05 I |
Issuance Date |
2016-09-28 |
Abatement Due Date |
2016-10-11 |
Current Penalty |
2850.0 |
Initial Penalty |
2850.0 |
Final Order |
2016-11-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: On or about March 30, 2016, at the above addressed job site, employees were exposed to a fall hazard of about 9 feet while using an extension ladder that did not conform with the 1:4 horizontal-to-vertical ratio. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261060 A |
Issuance Date |
2016-09-28 |
Abatement Due Date |
2016-10-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-11-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. On or about March 30, 2016, at the above addressed job site, employees who had not been provided training in the use of ladders were exposed to a fall hazard of about 9 feet while working from an extension ladder. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2016-09-28 |
Abatement Due Date |
2016-10-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-11-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about March 30, 2016, at the above addressed job site, the employer did not implement, develop and make available a written hazard communication program for employees who were exposed to and handling Titebond Weatherproof Subfloor Adhesive while installing stucco corner bead mesh. |
|
|
341244556
|
0418800
|
2016-02-11
|
1412 NE 6TH ST., FORT LAUDERDALE, FL, 33304
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-02-11
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2021-09-22
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2016-03-23 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2016-04-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about 11 February, 2016, at the above addressed jobsite, two employees were working on the edge of a new home under construction without the use of fall protection, exposing the employees to a fall hazard of up to approximately 13 feet. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2016-03-23 |
Abatement Due Date |
2016-04-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-04-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about 11 February, 2016, at the above addressed jobsite, two employees were working on the edge of a new home under construction without the employer providing fall protection training, exposing the employees to a fall hazard of up to approximately 13 feet. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19030019 D01 |
Issuance Date |
2016-12-20 |
Abatement Due Date |
2017-02-08 |
Current Penalty |
400.0 |
Initial Penalty |
400.0 |
Final Order |
2017-01-17 |
Nr Instances |
2 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: On or about 08/31/2016, the employer did not send abatement documentation for Citation 1/Item 1b, contained in Inspection #1124455, which was issued on 04/04/2016. |
|
|