Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-11-12
|
Emphasis |
L: FALL
|
Case Closed |
2022-02-03
|
Related Activity
Type |
Referral |
Activity Nr |
1656341 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1492420 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2020-12-09 |
Abatement Due Date |
2021-01-28 |
Current Penalty |
1850.4 |
Initial Penalty |
3084.0 |
Final Order |
2021-01-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about September 10, 2020 and at times prior, at the fabrication shop, the employer did not develop, implement, and/or maintain at the workplace a written hazard communication program for employees handling hazardous materials such as but not limited to Amerimix Colored Mortar Quickrete Portland Cement Based Concrete Products. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2020-12-09 |
Abatement Due Date |
2021-01-28 |
Current Penalty |
2313.6 |
Initial Penalty |
3856.0 |
Final Order |
2021-01-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) On or about September 8, 2020 and at times prior, the employer did not ensure that scaffold and scaffold components were inspected by a competent person before each work shift, and after any occurrence which affects a scaffolds structural integrity, exposing employees to a fall hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2020-12-09 |
Abatement Due Date |
2021-01-28 |
Current Penalty |
2313.6 |
Initial Penalty |
3856.0 |
Final Order |
2021-01-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) On or about September 8, 2020 and at times prior, the employer did not ensure that scaffold and scaffold components were erected, disassemble or altered without supervision and direction of a qualified competent person, in that, the scaffold system was altered by moving wallboards to reach a higher level, exposing employees to fall hazard. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260454 A |
Issuance Date |
2020-12-09 |
Abatement Due Date |
2021-01-28 |
Current Penalty |
2313.6 |
Initial Penalty |
3856.0 |
Final Order |
2021-01-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) On or about September 10, 2020 and at times prior, at the north side of the commercial building, the employer did not develop and implement a training program for employees on the recognition, evaluation, and control of hazards associated with scaffold operations, exposing employees to a fall hazard. |
|
|