Search icon

FRAMING CRAZY FOOLS INC - Florida Company Profile

Company Details

Entity Name: FRAMING CRAZY FOOLS INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

FRAMING CRAZY FOOLS INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 03 Feb 2015 (10 years ago)
Date of dissolution: 25 Sep 2020 (5 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2020 (5 years ago)
Document Number: P15000011246
FEI/EIN Number 47-2991315

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 7655 PINACLE DR, JACKSONVILLE, FL, 32244, US
Mail Address: 7655 PINACLE DR, JACKSONVILLE, FL, 32244, US
ZIP code: 32244
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MOFFETT RONALD President 7655 PINACLE DR, JACKSONVILLE, FL, 32244
MOFFETT RONALD Agent 7655 PINACLE DR, JACKSONVILLE, FL, 32244

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2020-09-25 - -
AMENDMENT 2019-03-28 - -
REGISTERED AGENT ADDRESS CHANGED 2019-03-28 7655 PINACLE DR, JACKSONVILLE, FL 32244 -
CHANGE OF MAILING ADDRESS 2019-03-28 7655 PINACLE DR, JACKSONVILLE, FL 32244 -
REGISTERED AGENT NAME CHANGED 2019-03-28 MOFFETT, RONALD -
CHANGE OF PRINCIPAL ADDRESS 2019-03-28 7655 PINACLE DR, JACKSONVILLE, FL 32244 -
REINSTATEMENT 2017-01-12 - -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2016-09-23 - -

Documents

Name Date
Amendment 2019-03-28
ANNUAL REPORT 2019-01-29
ANNUAL REPORT 2018-04-09
REINSTATEMENT 2017-01-12
Domestic Profit 2015-02-03

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341510915 0419700 2016-05-31 3663 ROYAL PALM KEY, JACKSONVILLE BEACH, FL, 32250
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2016-05-31
Emphasis L: FALL, P: FALL
Case Closed 2018-09-12

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2016-06-23
Current Penalty 1440.0
Initial Penalty 1440.0
Final Order 2016-07-25
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface, and the ladder side rails did not extend at least 3 feet (.9m) above the upper landing surface to which the ladder was used to gain access: a. On May 31, 2016, on the lower level roof, the ladder used to access the upper level roof did not extend 3 feet above the landing, exposing employees to a fall hazard.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2016-06-23
Current Penalty 3600.0
Initial Penalty 3600.0
Final Order 2016-07-25
Nr Instances 2
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, a personal fall arrest system, or an alternative fall protection measure as provided by another provision in paragraph (b) of this section: a. Employees performing framing work on the 8:12 pitch roof were not protected from an 18 feet fall hazard by the use of a fall protection system. b. Employees cutting wood on the 3:12 pitch roof were not protected from a 9 feet fall hazard by the use of a fall protection system. Framing Crazy Fools was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1111677, citation number 1, item number 1 and was affirmed as a final order on January 4, 2016, with respect to a workplace located at 3622 Paradise Way, Jacksonville Beach, Florida 32250.
Citation ID 03001
Citaton Type Other
Standard Cited 19261052 C01
Issuance Date 2016-06-23
Abatement Due Date 2016-06-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-07-25
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: a. On May 31, 2016, inside the house, the lower level of stairs from the 1st floor to the 2nd level floor did not have a handrail, exposing employees to a 4 feet fall hazard.
341116770 0419700 2015-12-14 3622 PARADISE WAY, JACKSONVILLE BEACH, FL, 32250
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-12-14
Emphasis L: FALL, P: FALL
Case Closed 2016-08-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-12-17
Current Penalty 2940.0
Initial Penalty 4900.0
Final Order 2016-01-12
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about December 14, 2015, at the Northeast side of the two-story house, three employees framing the sub-fascia and valley were exposed to a 23 feet 8 inches fall hazard to ground level without the use of personal fall arrest system, safety net system or guardrail system.