Search icon

TAMPA STUCCO & PAINTING INC. - Florida Company Profile

Company Details

Entity Name: TAMPA STUCCO & PAINTING INC.
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

TAMPA STUCCO & PAINTING INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 22 Dec 2014 (10 years ago)
Date of dissolution: 25 Sep 2015 (10 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2015 (10 years ago)
Document Number: P14000101171
Address: 8709 LONG NEEDLES CT, APT. B, TAMPA, FL, 33604
Mail Address: 8709 LONG NEEDLES CT, APT. B, TAMPA, FL, 33604
ZIP code: 33604
County: Hillsborough
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MIERES ARMANDO President 8709 LONG NEEDLES CT APT B, TAMPA, FL, 33604
MIERES ARMANDO Agent 8709 LONG NEEDLES CT, TAMPA, FL, 33604

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -

Documents

Name Date
Domestic Profit 2014-12-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340144294 0420600 2014-12-17 2504 W CREST AVE, TAMPA, FL, 33611
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-12-17
Emphasis L: EISAOF, L: FALL
Case Closed 2017-11-03

Related Activity

Type Complaint
Activity Nr 927292
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2015-02-09
Abatement Due Date 2015-02-20
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-03-10
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) At the construction on 2504 W Crest Avenue in Tampa: A) The three tiers scaffold system facing the north side were not fully planked and employees were exposed to a fall of approximately 12'-8", on or about 12/17/2014. B) The scaffold system that rested on the roof of the north porch was not fully planked and employees were exposed to a fall of approximately 15'-6", on or about 12/17/2014. C) The scaffold system facing the west side of the building was not fully planked and employees were exposed to a fall of approximately 14'-8", on or about 12/17/2014.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2015-02-09
Abatement Due Date 2015-02-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-10
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. At the construction on 2504 W Crest Avenue in Tampa: A) The three tiers scaffold system facing the north side had no fall protection and employees were exposed to a fall of approximately 12'-8", on or about 12/17/2014. B) The scaffold system that rested on the roof of the north porch had no fall protection and employees were exposed to a fall of approximately 15'-6", on or about 12/17/2014. C) The scaffold system facing the west side of the building had no fall protection and employees were exposed to a fall of approximately 14'8", on or about 12/17/2014.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2015-02-09
Abatement Due Date 2015-02-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-10
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: At the construction on 2504 W Crest Avenue in Tampa: A) The three tiers scaffold system facing the north had 4 braces missing and employees were exposed to a fall of approximately 12'-8", on or about 12/17/2014. B) The scaffold system that rested on the roof of the north porch had 1 brace missing and employees were exposed to a fall of approximately 15'-6", on or about 12/17/2014. C) The scaffold system facing the west side of the building had 1 brace missing and employees were exposed to a fall of approximately 14'-8", on or about 12/17/2014.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2015-02-09
Abatement Due Date 2015-02-20
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-03-10
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: At the construction site in 2504 W Crest Avenue in Tampa: a) The legs of the three tiered scaffold system facing the north side had no base plates, on or about 12/17/2014. b) The legs of the three tiered scaffold system facing the west side had no base plates, on or about 12/17/2014.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2015-02-09
Abatement Due Date 2015-02-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-10
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: At the construction in 2504 W Crest Avenue in Tampa: (a) An employee was observed standing on a platform and the platform was rested on a concrete block, exposing employees to a fall of approximately 15'-6", on or about 12/17/2014. (b)The leg of the scaffold system on the roof of the north porch rested on a concrete block, on or about 12/17/2014.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2015-02-09
Abatement Due Date 2015-02-20
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-03-10
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. At the construction in 2504 W Crest Avenue in Tampa: A) The three tiers scaffold system facing the north side had no safe access and employees were exposed to a fall of approximately 12'-8" on or about 12/17/2014. B) The scaffold system that rested on the roof of the north porch had no safe access and employees were exposed to a fall of approximately 15'-6" on or about 12/17/2014. C) The scaffold system facing the west side of the building had no safe access and employees were exposed to a fall of approximately 14'-8" on or about 12/17/2014.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2015-02-09
Abatement Due Date 2015-02-20
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-03-10
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. A) At the construction on 2504 W Crest Avenue in Tampa, employees using a scaffold system were not trained, exposing them to a fall hazard up to 12'-8", on or about 12/17/2014.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2015-02-09
Abatement Due Date 2015-02-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-10
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: A) At the construction on 2504 W Crest Avenue in Tampa, employees working on the roof of the north porch, exposing them to a fall hazard up to 12'-8", did not received training, on or about 12/17/2014.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2015-02-09
Abatement Due Date 2015-02-20
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-03-10
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. A) At the construction in 2504 W Crest Avenue in Tampa, an employee was working at the roof of the north porch. The employee was exposed to a fall of approximately 12'-8", on or about 12/17/2014.