Entity Name: | CB SOUTHERN CONSTRUCTION INC |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
CB SOUTHERN CONSTRUCTION INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 26 Nov 2014 (10 years ago) |
Date of dissolution: | 22 Sep 2017 (8 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 22 Sep 2017 (8 years ago) |
Document Number: | P14000095873 |
FEI/EIN Number |
47-2368143
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 136 SHERIDAN AVE, LONGWOOD, FL, 32750, US |
Mail Address: | 136 SHERIDAN AVE, LONGWOOD, FL, 32750, US |
ZIP code: | 32750 |
County: | Seminole |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
BERGERON CHRISTOPHER R | President | 136 SHERIDAN AVE, LONGWOOD, FL, 32750 |
BERGERON CHRISTOPHER R | Agent | 136 SHERIDAN AVE, LONGWOOD, FL, 32750 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2017-09-22 | - | - |
REGISTERED AGENT ADDRESS CHANGED | 2016-10-12 | 136 SHERIDAN AVE, LONGWOOD, FL 32750 | - |
REINSTATEMENT | 2016-10-12 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2016-10-12 | 136 SHERIDAN AVE, LONGWOOD, FL 32750 | - |
CHANGE OF MAILING ADDRESS | 2016-10-12 | 136 SHERIDAN AVE, LONGWOOD, FL 32750 | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2016-09-23 | - | - |
REGISTERED AGENT NAME CHANGED | 2015-11-10 | BERGERON, CHRISTOPHER R | - |
REINSTATEMENT | 2015-11-10 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2015-09-25 | - | - |
Name | Date |
---|---|
REINSTATEMENT | 2016-10-12 |
REINSTATEMENT | 2015-11-10 |
Domestic Profit | 2014-11-26 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341836971 | 0420600 | 2016-10-13 | 5818 RONALD REGAN PKWAY, DAVENPORT, FL, 33836 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1183637 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2016-11-03 |
Current Penalty | 2244.6 |
Initial Penalty | 3741.0 |
Final Order | 2016-11-29 |
Nr Instances | 3 |
Nr Exposed | 22 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. Building 11, employees of United Florida Construction, Inc. were exposed to a 10 foot fall hazard, in that, fall protection was not used during framing work at the second floor balconies of the building, on or about 10/13/2016. b. Building 8, employees of United Florida Construction, Inc. were exposed to a 20 foot fall hazard, in that, fall protection was not used during roof joist framing work, on or about 10/13/2016. c. Building 8 and 11, employees of United Florida Construction, Inc. were exposed to a 10 foot fall hazard, in that, fall protection was not used during framing work at the second floor windows where standard railings were not installed on all window openings, on or about 10/13/2016. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260405 A02 II I |
Issuance Date | 2016-11-03 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2016-11-29 |
Nr Instances | 1 |
Nr Exposed | 22 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: a. At the yard area, employees of United Florida Construction, Inc. were exposed to an electrical hazard, in that, extension cords were run across the road and were subject to getting run over by vehicular traffic without being protected from damage, on or about 10/13/2016. |
Date of last update: 01 Apr 2025
Sources: Florida Department of State