Entity Name: | MJP MASONRY, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
MJP MASONRY, INC. is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 12 Nov 2014 (10 years ago) |
Date of dissolution: | 22 Sep 2023 (2 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 22 Sep 2023 (2 years ago) |
Document Number: | P14000092188 |
FEI/EIN Number |
47-2331279
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 1085 W 27 ST, HIALEAH, FL, 33010, US |
Mail Address: | 1085 W 27 ST, HIALEAH, FL, 33010, US |
ZIP code: | 33010 |
County: | Miami-Dade |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
PALACIO MARLON J | President | 1085 W 27 ST, HIALEAH, FL, 33010 |
PALACIO MARLON J | Agent | 1085 W 27 ST, HIALEAH, FL, 33010 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2023-09-22 | - | - |
REINSTATEMENT | 2021-02-22 | - | - |
REGISTERED AGENT NAME CHANGED | 2021-02-22 | PALACIO, MARLON J | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2019-09-27 | - | - |
CHANGE OF PRINCIPAL ADDRESS | 2018-04-17 | 1085 W 27 ST, HIALEAH, FL 33010 | - |
CHANGE OF MAILING ADDRESS | 2018-04-17 | 1085 W 27 ST, HIALEAH, FL 33010 | - |
REGISTERED AGENT ADDRESS CHANGED | 2018-04-17 | 1085 W 27 ST, HIALEAH, FL 33010 | - |
Name | Date |
---|---|
ANNUAL REPORT | 2022-04-29 |
REINSTATEMENT | 2021-02-22 |
ANNUAL REPORT | 2018-04-17 |
ANNUAL REPORT | 2017-05-01 |
ANNUAL REPORT | 2016-07-07 |
ANNUAL REPORT | 2015-05-01 |
Domestic Profit | 2014-11-12 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342172707 | 0418800 | 2017-03-14 | 2599 NW 37TH AVENUE, MIAMI, FL, 33142 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1217273 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1217265 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2017-08-25 |
Current Penalty | 1793.0 |
Initial Penalty | 1793.0 |
Final Order | 2017-11-06 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles: On or about 3/10/2017, at the above addressed jobsite, an employee was exposed to struck-by hazard while using a cement saw to cut cement block without using any eye protection. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2017-08-25 |
Current Penalty | 2391.0 |
Initial Penalty | 2391.0 |
Final Order | 2017-11-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about 3/10/2017, at the above addressed jobsite, employees were exposed to a fall hazard while using the crossbraces to climb up a two-tier scaffold to erect a cement wall. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19101200 E01 |
Issuance Date | 2017-08-25 |
Abatement Due Date | 2017-10-13 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-11-06 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met (Construction Reference: 1926.59)(a)): On or about 3/10/2017, at the above addressed jobsite, the employer did not develop or implement a written hazard communication program to address hazards related to substances that contain chemicals such as silica while employees were cutting cement blocks without any respiratory protection. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION. |
Citation ID | 03001 |
Citaton Type | Other |
Standard Cited | 19030019 D01 |
Issuance Date | 2018-01-08 |
Abatement Due Date | 2018-02-26 |
Current Penalty | 311.0 |
Initial Penalty | 311.0 |
Final Order | 2018-03-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: The employer did not provide abatement certification and documentation for OSHA inspection #1217270, that was issued on 08/25/2017, and was due on 10/13/2017, for Citation 02, Item 001. |
Inspection Type | Prog Related |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2016-09-19 |
Emphasis | L: FALL |
Case Closed | 2018-11-17 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2016-10-26 |
Current Penalty | 1282.8 |
Initial Penalty | 2138.0 |
Final Order | 2016-11-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 19 September 2016, and at times prior thereto, workers were performing stucco work using a second tier tubular welded frame scaffold that was not fully planked at the level they were working at, exposing the workers to a fall hazard of approximately 10 feet. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 VII |
Issuance Date | 2016-10-26 |
Current Penalty | 1282.8 |
Initial Penalty | 2138.0 |
Final Order | 2016-11-15 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. On or about 19 September 2016, and at times prior thereto, workers were performing stucco work using a second tier tubular welded frame scaffold without fall protection, exposing the workers to a fall hazard of approximately 10 feet. |