Entity Name: SUNRISE ALL CONTRACTOR CORP
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation

SUNRISE ALL CONTRACTOR CORP is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock.
In Florida, Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 28 Jul 2014 (11 years ago)
Date of dissolution: 25 Sep 2015 (9 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2015 (9 years ago)
Document Number: P14000063114
Address: 3674 NW 111TH AVE, SUNRISE, FL 33351
Mail Address: 3674 NW 111TH AVE, SUNRISE, FL 33351
ZIP code: 33351
County: Broward
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
SANJURJO CORDERO, YAMIL Agent 3674 NW 111TH AVE, SUNRISE, FL 33351
SANJURJO CORDERO, YAMIL President 3674 NW 111TH AVE, SUNRISE, FL 33351
SANJURJO CORDERO, YAMIL Vice Treasurer 3674 NW 111TH AVE, SUNRISE, FL 33351
SANJURJO CORDERO, YAMIL Director 3674 NW 111TH AVE, SUNRISE, FL 33351

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -

Documents

Name Date
Domestic Profit 2014-07-28

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340409333 0418800 2015-02-18 499 S FEDERAL HIGHWAY, BOCA RATON, FL, 33432
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-02-18
Emphasis L: FALL, P: FALL
Case Closed 2021-09-28

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2015-04-03
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2016-01-28
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about February 18, 2015, at the above addressed job site, an employee was exposed to an eye injury while using a pneumatic nail gun without eye protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2015-04-03
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2016-01-28
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. On or about February 18, 2015, at the above addressed job site, an employee was using a scaffold that was not fully planked while exposed to 10 feet 2 inch fall hazard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2015-04-03
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2016-01-28
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a. On or about February 18, 2015, at the above addressed job site, an employee was exposed to a 10 feet 2 inch fall hazard when working from a scaffold that was not inspected by a competent person.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2015-04-03
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2016-01-28
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a. On or about February 18, 2015, at the above addressed job site, an employee was exposed to a 10 feet 2 inch fall hazard while working from a scaffold that lacked a means of fall protection.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2015-04-03
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2016-01-28
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. On or about February 18, 2015, at the above addressed job site, an employee was exposed to a 10 feet-2 inches fall hazard while working from a form wall without a means of fall protection.