Search icon

REE CONSTRUCTION INC

Company Details

Entity Name: REE CONSTRUCTION INC
Jurisdiction: FLORIDA
Filing Type: Florida Profit Corporation
Status: Inactive
Date Filed: 21 Jul 2014 (11 years ago)
Date of dissolution: 23 Sep 2016 (8 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2016 (8 years ago)
Document Number: P14000061355
FEI/EIN Number 47-1388706
Address: 4255 VERMONT AVE, LAKE WORTH, FL 33461
Mail Address: 4255 VERMONT AVE, LAKE WORTH, FL 33461
ZIP code: 33461
County: Palm Beach
Place of Formation: FLORIDA

Agent

Name Role Address
ESCOBAR-EFRAIN, ROQUE Agent 4255 VERMONT AVE, LAKE WORTH, FL 33461

President

Name Role Address
ESCOBAR-EFRAIN, ROQUE President 4255 VERMONT AVE, LAKE WORTH, FL 33461

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2016-09-23 No data No data

Documents

Name Date
ANNUAL REPORT 2015-04-30
Domestic Profit 2014-07-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341028959 0418800 2015-11-02 201 SW MONTEREY ROAD, STUART, FL, 34994
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-11-02
Emphasis L: FALL, P: FALL
Case Closed 2020-01-10

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2015-11-16
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2016-02-10
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: On or about November 2, 2015, at the above addressed site, an employee was exposed to a fall hazard when moving an aerial lift to perform stucco work while not wearing a harness with a lanyard attached to the boom or basket of that lift.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260453 B02 IX
Issuance Date 2015-11-16
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2016-02-10
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(ix): Controls for the articulating and extensible boom platforms were not clearly marked to identify their function: On or about November 2, 2015, at the above addressed site, an employee was exposed to a fall hazard while operating an aerial lift that had the operators panel controls covered with stucco material and were not plainly marked as to their function.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2015-11-16
Abatement Due Date 2015-12-04
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2016-02-10
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: On or about November 2, 2015, at the above addressed site, an employee was exposed to a fall hazard while not being provided with a training program that would enable him to recognize the hazards associated with the lift he was operating. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
340621135 0418800 2015-05-07 4908 NW 58TH ST, TAMARAC, FL, 33319
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-05-07
Emphasis L: FALL, P: FALL
Case Closed 2015-09-14

Related Activity

Type Inspection
Activity Nr 1062315
Safety Yes

Date of last update: 20 Feb 2025