Entity Name: | R CONTRERAS CONSTRUCTION, INC. |
Jurisdiction: | FLORIDA |
Filing Type: |
Florida Profit Corporation
R CONTRERAS CONSTRUCTION, INC. is structured as a Profit Corporation, also known as a C-Corporation, a business structure recognized as a separate legal entity from its owners. This structure offers the benefit of potential tax advantages and ease of raising capital through the issuance of stock. |
Status: |
Inactive
The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders. |
Date Filed: | 14 Jul 2014 (11 years ago) |
Date of dissolution: | 23 Sep 2016 (8 years ago) |
Last Event: | ADMIN DISSOLUTION FOR ANNUAL REPORT |
Event Date Filed: | 23 Sep 2016 (8 years ago) |
Document Number: | P14000059552 |
FEI/EIN Number |
47-1345481
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 260 N.E. 38TH STREET, #23, OAKLAND PARK, FL 33334 |
Mail Address: | 260 N.E. 38TH STREET, #23, OAKLAND PARK, FL 33334 |
ZIP code: | 33334 |
County: | Broward |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
CONTRERAS, RENALDO A | Agent | 260 N.E. 38TH STREET, #23, OAKLAND PARK, FL 33334 |
CONTRERAS, RENALDO A | President | 260 N.E. 38TH STREET, #23, OAKLAND PARK, FL 33334 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2016-09-23 | - | - |
REGISTERED AGENT NAME CHANGED | 2015-07-30 | CONTRERAS, RENALDO A | - |
Name | Date |
---|---|
ANNUAL REPORT | 2015-07-30 |
Domestic Profit | 2014-07-14 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340903863 | 0418800 | 2015-09-01 | 5647 HOLLYWOOD BLVD, HOLLYWOOD, FL, 33022 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2015-09-30 |
Current Penalty | 4900.0 |
Initial Penalty | 4900.0 |
Final Order | 2015-12-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. On or about September 1st, 2015, at the above addressed job site, employees were using a scaffold that was not fully planked while exposed to an approximate 22-foot fall hazard. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2015-09-30 |
Current Penalty | 3500.0 |
Initial Penalty | 3500.0 |
Final Order | 2015-12-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a. On or about September 1st, 2015, at the above addressed job site, employees did not have a means of access to a scaffold while exposed to an approximate 22-foot fall hazard. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 VII |
Issuance Date | 2015-09-30 |
Current Penalty | 4900.0 |
Initial Penalty | 4900.0 |
Final Order | 2015-12-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a. On or about September 1st, 2015, at the above addressed job site, an employee was exposed to an approximate 22-foot fall hazard while working from a scaffold that lacked a means of fall protection. |
Date of last update: 20 Feb 2025
Sources: Florida Department of State