Entity Name: | BROTHERS B CONSTRUCTION CORP |
Jurisdiction: | FLORIDA |
Filing Type: |
Domestic Profit
BROTHERS B CONSTRUCTION CORP is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act. |
Status: |
Active
The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness. |
Date Filed: | 24 Jun 2014 (11 years ago) |
Last Event: | REINSTATEMENT |
Event Date Filed: | 28 Oct 2019 (5 years ago) |
Document Number: | P14000054698 |
FEI/EIN Number |
47-1185564
Federal Employer Identification (FEI) Number assigned by the IRS. |
Address: | 2912 23RD ST SW, LEHIGH ACRES, FL, 33976, UN |
Mail Address: | 2912 23RD ST SW, LEHIGH ACRES, FL, 33976 |
ZIP code: | 33976 |
County: | Lee |
Place of Formation: | FLORIDA |
Name | Role | Address |
---|---|---|
BADILLO FLAVIO | President | 2912 23TH ST SW, LEHIGH ACRES, FL, 33976 |
RICARDO BADILLO | Vice President | 116 DALEVIOW AVE, LEHIGH ACRES, FL, 33971 |
BADILLO FLAVIO | Agent | 2912 23RD ST SW, LEHIGH ACRES, FL, 33976 |
Event Type | Filed Date | Value | Description |
---|---|---|---|
REINSTATEMENT | 2019-10-28 | - | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2019-09-27 | - | - |
REINSTATEMENT | 2018-10-24 | - | - |
REGISTERED AGENT NAME CHANGED | 2018-10-24 | BADILLO, FLAVIO | - |
ADMIN DISSOLUTION FOR ANNUAL REPORT | 2018-09-28 | - | - |
Name | Date |
---|---|
ANNUAL REPORT | 2024-04-03 |
ANNUAL REPORT | 2023-01-24 |
ANNUAL REPORT | 2022-04-14 |
ANNUAL REPORT | 2021-04-30 |
ANNUAL REPORT | 2020-01-30 |
REINSTATEMENT | 2019-10-28 |
REINSTATEMENT | 2018-10-24 |
ANNUAL REPORT | 2017-03-15 |
ANNUAL REPORT | 2016-04-30 |
ANNUAL REPORT | 2015-05-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340319672 | 0420600 | 2015-06-04 | 11501 SUMMERVIEW WAY, FORT MYERS, FL, 33913 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2015-07-01 |
Current Penalty | 1020.0 |
Initial Penalty | 1700.0 |
Final Order | 2015-07-29 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. Along the top of the exterior cinder block walls, hard hats were not worn when receiving wooden truss frames from a mobile crane exposing employees to a struck by hazard, on or about 6/4/2015. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2015-07-01 |
Current Penalty | 612.0 |
Initial Penalty | 1020.0 |
Final Order | 2015-07-29 |
Nr Instances | 3 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. In the roof truss framing, eye protection was not worn when operating a Super-Framer nail gun model CN890F, exposing employees to a struck by hazard, on or about 6/4/15. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2015-07-01 |
Current Penalty | 1224.0 |
Initial Penalty | 2040.0 |
Final Order | 2015-07-29 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On top of the exterior cinder block walls, fall protection was not provided when receiving wood trusses that were being flown by a mobile crane exposing employees to a fall hazard, on or about 6/4/15. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2015-07-01 |
Current Penalty | 816.0 |
Initial Penalty | 1360.0 |
Final Order | 2015-07-29 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. Along the east exterior wall, the portable extension ladder used to climb onto the exterior wall only extended two rungs (two feet) past the landing surface, exposing the employees to a fall hazard, on or about 6/4/15. |