Search icon

CASTROS PUMPING SERVICE INC - Florida Company Profile

Company Details

Entity Name: CASTROS PUMPING SERVICE INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

CASTROS PUMPING SERVICE INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 06 Jun 2014 (11 years ago)
Date of dissolution: 23 Sep 2016 (9 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 23 Sep 2016 (9 years ago)
Document Number: P14000049792
FEI/EIN Number 47-1088733

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 6774 GLENBROOK DR, LAKELAND, FL, 33811, US
Mail Address: 6774 GLENBROOK DR, LAKELAND, FL, 33811, US
ZIP code: 33811
County: Polk
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
RANGEL ARIEL Jr. President 6774 GLENBROOK DR, LAKELAND, FL, 33811
RANGEL ARIEL Jr. Agent 6774 GLENBROOK DR, LAKELAND, FL, 33811

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2016-09-23 - -
AMENDMENT 2015-10-21 - -
CHANGE OF PRINCIPAL ADDRESS 2015-10-21 6774 GLENBROOK DR, LAKELAND, FL 33811 -
CHANGE OF MAILING ADDRESS 2015-10-21 6774 GLENBROOK DR, LAKELAND, FL 33811 -
REGISTERED AGENT NAME CHANGED 2015-09-19 RANGEL, ARIEL, Jr. -

Documents

Name Date
Amendment 2015-10-21
AMENDED ANNUAL REPORT 2015-09-19
ANNUAL REPORT 2015-04-30
Domestic Profit 2014-06-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339900383 0420600 2014-10-22 4366 - 4332 FENWOOD COURT BLDG #6, WESLEY CHAPEL, FL, 33544
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-10-22
Emphasis L: FALL, P: FALL
Case Closed 2017-10-24

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2014-10-31
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2014-11-21
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment was not used when machines or operations presented potential eye or face injury: (a). At Building #6 in the Lennar Townhome development of Wesley Chapel the employee pumping cement thru a 2 inch hose under pressure was not provided with eye or face protection to protect him from being struck-by splattering cement, on or about October 22, 2014.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-10-31
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2014-11-21
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: (a). At Building #6 in the Lennar Townhome development of Wesley Chapel where an employee walking the top of the concrete block wall of the two story building pumping cement into the wall was not protected from the 20-foot fall from the open side of the wall to the ground below, on or about October 22, 2014.

Date of last update: 01 Apr 2025