Search icon

MARTINEZ STUCCO SERVICES INC - Florida Company Profile

Company Details

Entity Name: MARTINEZ STUCCO SERVICES INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

MARTINEZ STUCCO SERVICES INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 03 Feb 2014 (11 years ago)
Last Event: REINSTATEMENT
Event Date Filed: 04 Jan 2023 (2 years ago)
Document Number: P14000010727
FEI/EIN Number 46-4729300

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 4217 Red Leaf Dr, NEW PORT RICHEY, FL, 34652, US
Mail Address: 4217 Red Leaf Dr, NEW PORT RICHEY, FL, 34652, US
ZIP code: 34652
County: Pasco
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MARTINEZ SERGIO President 4217 Red Leaf Dr, NEW PORT RICHEY, FL, 34652
MARTINEZ SERGIO Agent 4217 Red Leaf Dr, NEW PORT RICHEY, FL, 34652

Events

Event Type Filed Date Value Description
REINSTATEMENT 2023-01-04 - -
REGISTERED AGENT NAME CHANGED 2023-01-04 MARTINEZ, SERGIO -
ADMIN DISSOLUTION FOR ANNUAL REPORT 2021-09-24 - -
CHANGE OF PRINCIPAL ADDRESS 2015-04-29 4217 Red Leaf Dr, NEW PORT RICHEY, FL 34652 -
CHANGE OF MAILING ADDRESS 2015-04-29 4217 Red Leaf Dr, NEW PORT RICHEY, FL 34652 -
REGISTERED AGENT ADDRESS CHANGED 2015-04-29 4217 Red Leaf Dr, NEW PORT RICHEY, FL 34652 -

Documents

Name Date
ANNUAL REPORT 2024-04-29
REINSTATEMENT 2023-01-04
ANNUAL REPORT 2020-06-29
ANNUAL REPORT 2019-04-30
AMENDED ANNUAL REPORT 2018-08-27
ANNUAL REPORT 2018-01-17
ANNUAL REPORT 2017-01-25
ANNUAL REPORT 2016-04-22
ANNUAL REPORT 2015-04-29
Domestic Profit 2014-02-03

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340429620 0420600 2015-02-26 18228 ARBOR CREST DR, HUDSON, FL, 34667
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-02-26
Emphasis L: FALL, L: EISAX, L: EISAOF, P: FALL
Case Closed 2016-09-09

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2015-03-12
Abatement Due Date 2015-04-07
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2015-03-25
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a. Scaffold - during stucco operations on a welded frame scaffold, mud sills were not provided and exposed employees to fall hazards. Violation observed on or about 2/26/15.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2015-03-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a. Scaffold east side - guardrails were missing on the welded frame scaffold during stucco operations and exposed employees up to a 14 foot fall hazard. Violation observed on or about 2/26/15.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2015-03-12
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2015-03-25
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access: a. Scaffold - a ladder for access to the welded frame scaffold was not installed, in that, employees used end frames and railings for access and were exposed up to a 14 foot fall hazard. Violation observed on or about 2/26/15.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2015-03-12
Abatement Due Date 2015-04-28
Current Penalty 1440.0
Initial Penalty 2400.0
Final Order 2015-03-25
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a. Scaffold - employees who used a welded frame scaffold during stucco operations had not been trained in the safe use of the scaffold and the hazards associated with the use of the scaffold exposing employees up to a 14 foot fall hazard. Violation observed on or about 2/26/15.
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 C02 I
Issuance Date 2015-03-12
Abatement Due Date 2015-04-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-25
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a. Mixing area - the employer did not provide the information contained in Appendix D when 3M N95 dust masks were used. Violation observed on or about 2/26/15.
Citation ID 02002
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2015-03-12
Abatement Due Date 2015-04-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-25
Nr Instances 1
Nr Exposed 8
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. Mixing area - the employer did not have a written hazard communication program for employees exposed to chemical products such as, but not limited to, stucco mix. Violation observed on or about 2/26/15.
Citation ID 02003
Citaton Type Other
Standard Cited 19101200 G08
Issuance Date 2015-03-12
Abatement Due Date 2015-04-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-25
Nr Instances 1
Nr Exposed 8
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: a. Mixing area - the employer did not have a written hazard communication program for employees exposed to chemical products such as, but not limited to, stucco mix. Violation observed on or about 2/26/15.
Citation ID 02004
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2015-03-12
Abatement Due Date 2015-04-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-25
Nr Instances 1
Nr Exposed 8
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. Mixing area - the employer did not provide hazard communication training for employees exposed to chemical products such as, but not limited to, stucco mix. Violation observed on or about 2/26/15.

Date of last update: 02 Mar 2025