Inspection Type |
Fat/Cat
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-11-29
|
Case Closed |
2022-06-22
|
Related Activity
Type |
Accident |
Activity Nr |
1404585 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100101 B |
Issuance Date |
2019-03-20 |
Current Penalty |
2046.0 |
Initial Penalty |
3410.0 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to struck-by hazards while having a nitrogen cylinder not secured while in storage. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100169 B03 I |
Issuance Date |
2019-03-20 |
Current Penalty |
1705.2 |
Initial Penalty |
2842.0 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.169(b)(3)(i): Every air receiver was not equipped with an indicating pressure gauge (so located as to be readily visible): On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to struck-by hazards due to air receivers not equipped with an operational pressure gauge. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100244 A02 III |
Issuance Date |
2019-03-20 |
Current Penalty |
9282.0 |
Initial Penalty |
13260.0 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.244(a)(2)(iii): Loads were not cribbed, blocked or otherwise secured immediately after being raised with a jack: On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to caught-between hazards while working under loads that were not cribbed, blocked or secured. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100253 B02 IV |
Issuance Date |
2019-03-20 |
Current Penalty |
1363.8 |
Initial Penalty |
2273.0 |
Final Order |
2019-04-01 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to struck-by hazards while cylinders of oxygen and acetylene were stored without a valve cap. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 I |
Issuance Date |
2019-03-20 |
Current Penalty |
1363.8 |
Initial Penalty |
2273.0 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire: On or about 11/30/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to fire hazards while cylinders of oxygen and acetylene were stored together. |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19100303 C03 I |
Issuance Date |
2019-03-20 |
Current Penalty |
1363.8 |
Initial Penalty |
2273.0 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(c)(3)(i): Conductors were not spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices were not first spliced or joined to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose: On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, an air compressor had a splice on its cord covered with electrical plastic tape, exposing an employee to an electrical shock hazard. |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19100304 G05 |
Issuance Date |
2019-03-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to electrical hazards while an air compressor lacked a grounding conductor. |
|
Citation ID |
01006C |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV |
Issuance Date |
2019-03-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv). On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to electrical hazards while an air compressor had temporary wiring. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2019-03-20 |
Abatement Due Date |
2019-05-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, the employer did not implement and develop a written hazard communication program for employees exposed to chemical hazards associated with chemicals including but not limited to, nitrogen, acetylene, oxygen, oils and solvents at the workplace. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19101200 G01 |
Issuance Date |
2019-03-20 |
Abatement Due Date |
2019-05-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, the employer did not have the safety data sheets for employees exposed to chemical hazards while working with chemicals including but not limited to, nitrogen, acetylene, oxygen, oils and solvents at the workplace. |
|
|