Search icon

HAVILA PROFESSIONAL SERVICES CORP - Florida Company Profile

Company Details

Entity Name: HAVILA PROFESSIONAL SERVICES CORP
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

HAVILA PROFESSIONAL SERVICES CORP is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Active

The business entity is active. This status indicates that the business is currently operating and compliant with state regulations, suggesting a lower risk profile for lenders and potentially better creditworthiness.

Date Filed: 21 Nov 2013 (11 years ago)
Document Number: P13000094534
FEI/EIN Number 36-4774022

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 6332 QUARTERHORSE LN, Orlando, FL, 32818, US
Mail Address: 6332 QUARTERHORSE LN, Orlando, FL, 32818, US
ZIP code: 32818
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
AMADOR MENDOZA EDWIN President 6332 QUARTERHORSE LN, Orlando, FL, 32818
AMADOR MENDOZA EDWIN Agent 6332 QUARTERHORSE LN, Orlando, FL, 32818

Events

Event Type Filed Date Value Description
CHANGE OF PRINCIPAL ADDRESS 2019-05-01 6332 QUARTERHORSE LN, Orlando, FL 32818 -
CHANGE OF MAILING ADDRESS 2019-05-01 6332 QUARTERHORSE LN, Orlando, FL 32818 -
REGISTERED AGENT ADDRESS CHANGED 2019-05-01 6332 QUARTERHORSE LN, Orlando, FL 32818 -
REGISTERED AGENT NAME CHANGED 2018-04-27 AMADOR MENDOZA, EDWIN -

Documents

Name Date
ANNUAL REPORT 2024-03-18
ANNUAL REPORT 2023-05-01
ANNUAL REPORT 2022-04-13
ANNUAL REPORT 2021-04-28
ANNUAL REPORT 2020-06-30
ANNUAL REPORT 2019-05-01
ANNUAL REPORT 2018-04-27
ANNUAL REPORT 2017-05-01
ANNUAL REPORT 2016-02-17
ANNUAL REPORT 2015-05-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341561306 0420600 2016-06-20 313 CAPTIVA DR BUILDING #17, DAVENPORT, FL, 33896
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-06-20
Emphasis L: FALL, P: FALL
Case Closed 2018-02-09

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19261053 B06
Issuance Date 2016-06-23
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2016-07-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: a. At the north side of building 7, employees were exposed to a 15 foot fall hazard, in that, step ladders and non-self-supported extension ladders were used by standing the ladders on the pitched roof of the first floor and leaning them on the wall of the second floor without being supported from sliding off the roof, on or about 06/20/2016.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2016-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-07-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. At the north side of building 7, employees were exposed to an 11 foot fall hazard while standing on the roof of the first floor during fascia work at the overhung of the second floor roof, on or about 06/20/2016.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2016-06-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-07-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a. At the north side of building 7, employees were exposed to an 15 foot fall hazard, in that, an 8 foot step ladder was used as a non-self-supporting ladder by standing it on the pitched roof of the first floor and leaning it on the wall of the second floor, on or about 06/20/2016.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2016-06-23
Abatement Due Date 2016-08-10
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2016-07-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. At the north site of building 7, employees were exposed to a 15 foot fall hazard without being provided training and education relating to fall protection, hazard recognition, procedures to be followed to minimize these hazards and the proper use and limitation of fall protection equipment and fall protection systems, on or about 06/20/2016.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2016-06-23
Abatement Due Date 2016-08-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-07-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for employees using ladders and stairways, that enabled each employee to recognize hazards related to ladders and stairways, and the procedures to be followed to minimize these hazards: a. On site, employees used ladders to access the various work areas during soffit installation work without being provided ladder training to include at a minimum the following: 1. The nature of fall hazards in the work area. 2. The correct procedures for erecting, maintaining and disassembling the fall protection systems to be used. 3. The proper construction, use, placement, and care of handling of all stairways and ladders. 4. The maximum intended load-carrying capacities of ladders used and. 5. The OSHA standards on ladders and stairways on or about 06/20/2016.
Citation ID 02001
Citaton Type Other
Standard Cited 19260020 B01
Issuance Date 2016-06-23
Abatement Due Date 2016-08-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-07-11
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(1): A safety and health program was not initiated and/or maintained to provide compliance with the general safety and health provisions of the standard: a. The employer did not develop and implement a safety and health program to address the company policy on safety as well as the employer/employee responsibilities.

Date of last update: 02 May 2025

Sources: Florida Department of State