Search icon

YR SERVICES OF ORLANDO INC - Florida Company Profile

Company Details

Entity Name: YR SERVICES OF ORLANDO INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

YR SERVICES OF ORLANDO INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 07 Nov 2013 (12 years ago)
Date of dissolution: 25 Sep 2015 (10 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 25 Sep 2015 (10 years ago)
Document Number: P13000091351
FEI/EIN Number 46-4060581

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 6109 HOLIDAY HILL LN, ORLANDO, FL, 32808, US
Mail Address: 6109 HOLIDAY HILL LN, ORLANDO, FL, 32808, US
ZIP code: 32808
County: Orange
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
TEJADA DOUGLAS Agent 6109 HOLIDAY HILL LN, ORLANDO, FL, 32808
TEJADA DOUGLAS President 6109 HOLIDAY HILL LN, ORLANDO, FL, 32808

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2015-09-25 - -

Documents

Name Date
ANNUAL REPORT 2014-04-30
Domestic Profit 2013-11-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339658916 0420600 2014-04-02 1853 PEAKHAM PL, APOPKA, FL, 32703
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-04-02
Emphasis L: FALL, P: FALL
Case Closed 2017-11-03

Related Activity

Type Inspection
Activity Nr 965878
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-05-05
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-06-13
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. At the job site, employees installing wood decking from the top of the roof were exposed to 19 foot 4 inch and a 13 foot 5 inch fall hazard, in that, the use of fall protection was not enforced and not available. The roof pitch was 6:12 and 3:12. Violation observed on or about 04/02/2014.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A02
Issuance Date 2014-05-05
Abatement Due Date 2014-05-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-06-13
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii) a. At the job site, an employee installing decking was not provided with fall protection training, on or about 04/02/2014.

Date of last update: 01 May 2025