Search icon

EMCO RAIN GUTTERS INC - Florida Company Profile

Company Details

Entity Name: EMCO RAIN GUTTERS INC
Jurisdiction: FLORIDA
Filing Type: Domestic Profit

EMCO RAIN GUTTERS INC is structured as a Domestic Profit Corporation, which, in Florida signifies a Profit Corporation (also known as a C-Corporation). This business structure is recognized as a separate legal entity from its owners. This offers shareholders the benefit of limited liability protection, safeguarding their personal assets from the corporation's debts and obligations, and facilitates raising capital through the issuance of stock. In Florida, Domestic Profit Corporations are governed by Title XXXVI, Chapter 607, Florida Statutes – Florida Business Corporation Act.

Status: Inactive

The business entity is inactive. This status may signal operational issues or voluntary closure, raising concerns about the business's ability to repay loans and requiring careful risk assessment by lenders.

Date Filed: 24 Oct 2013 (11 years ago)
Date of dissolution: 27 Sep 2019 (5 years ago)
Last Event: ADMIN DISSOLUTION FOR ANNUAL REPORT
Event Date Filed: 27 Sep 2019 (5 years ago)
Document Number: P13000087271
FEI/EIN Number NOT APPLICABLE

Federal Employer Identification (FEI) Number assigned by the IRS.

Address: 404 BEVERLY LANE, JACKSONVILLE, FL, 32254
Mail Address: 404 BEVERLY LANE, JACKSONVILLE, FL, 32254
ZIP code: 32254
County: Duval
Place of Formation: FLORIDA

Key Officers & Management

Name Role Address
MIDYETTE STEVE President 404 BEVERLY LANE, JACKSONVILLE, FL, 32254
SMALL BUSINESS ASSOCIATES INC. Agent -

Events

Event Type Filed Date Value Description
ADMIN DISSOLUTION FOR ANNUAL REPORT 2019-09-27 - -

Documents

Name Date
ANNUAL REPORT 2018-03-06
ANNUAL REPORT 2017-02-13
ANNUAL REPORT 2016-04-14
ANNUAL REPORT 2015-04-14
ANNUAL REPORT 2014-04-30
Domestic Profit 2013-10-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341107688 0419700 2015-12-09 1023 LEMON DROP LANE LOT 557-3, MIDDLEBURG, FL, 32050
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-12-09
Emphasis L: FALL, P: FALL
Case Closed 2020-08-18

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2015-12-22
Current Penalty 5390.0
Initial Penalty 10780.0
Final Order 2016-01-28
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. Employees performing roofing work on a 6:12 pitched roof at elevations are not being protected from an 18-foot fall hazards by use of a fall protection system. The EMCO Rain Gutters, Incorporated was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 997654, citation number 1, item number 2 and was affirmed as a final order on October 31, 2014, with respect to a workplace located at 14993 Bartram Trail CK BL, Saint Johns, Florida 32259.
339976540 0419700 2014-10-01 14993 BARTRAM CK BL, SAINT JOHNS, FL, 32259
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-10-01
Emphasis L: FALL, P: FALL
Case Closed 2020-08-18

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260102 A01
Issuance Date 2014-10-07
Current Penalty 3168.0
Initial Penalty 5280.0
Final Order 2014-10-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about October 1, 2014, an employee using a pneumatic nail gun was not wearing safety glasses, exposing himself to being hit by nails or flying debris. The Emco Rain Gutters, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (name previously cited standard), which was contained in OSHA inspection number 967569, citation number 1, item number 1 and was affirmed as a final order on May 21, 2014, with respect to a workplace located at 1475 Lantern Light Trail, Lot 301, Middleburg, Florida 32068.
Citation ID 01002
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2014-10-07
Current Penalty 3168.0
Initial Penalty 5280.0
Final Order 2014-10-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about October 1, 2014, on a 6:12 pitch roof, an employee performing roofing operations was not protected from an 8-foot 6-inch fall hazard by use of a fall protection system . The Emco Rain Gutters, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard (name previously cited standard), which was contained in OSHA inspection number 967569, citation number 1, item number 2a and was affirmed as a final order on May 21, 2014, with respect to a workplace located at 1475 Lantern Light Trail, Lot 301, Middleburg, Florida 32068.
339675696 0419700 2014-04-14 1475 LANTERN LIGHT TRAIL PINE RIDGE, LOT 301, MIDDLEBURG, FL, 32068
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-04-14
Emphasis L: FALL, P: FALL
Case Closed 2015-08-24

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2014-04-24
Current Penalty 1000.0
Initial Penalty 1600.0
Final Order 2014-05-20
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about April 14, 2014, on the roof, employees using pneumatic air nailers while installing roofing components were not using eye protection, exposing themselves to eye injuries.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-04-24
Current Penalty 1600.0
Initial Penalty 2800.0
Final Order 2014-05-20
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a. On or about April 14, 2014, on the 5:12 pitch roof, employees were installing shingles into the residential roof without the use of a fall protection system, exposing themselves to an 8 feet 10-inch fall hazard.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2014-04-24
Abatement Due Date 2014-05-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-20
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a. On or about April 14, 2014, employees working from elevations were not trained about fall protection.